Antimony Powder-Modified Carbon Paste Electrodes for Electrochemical Stripping Determination of Trace Heavy Metals
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F11%3A39892631" target="_blank" >RIV/00216275:25310/11:39892631 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.electacta.2011.05.048" target="_blank" >http://dx.doi.org/10.1016/j.electacta.2011.05.048</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.electacta.2011.05.048" target="_blank" >10.1016/j.electacta.2011.05.048</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Antimony Powder-Modified Carbon Paste Electrodes for Electrochemical Stripping Determination of Trace Heavy Metals
Popis výsledku v původním jazyce
A new type of the antimony electrode based on a carbon paste bulk-modified with antimony powder (Sb-CPE) is presented for the determination of cadmium(II) and lead(II) ions at the ug L-1 concentration level, when using SWASV or stripping chronopotentiometric protocol. Key-operational parameters, including the amount of antimony powder in the carbon paste mixture, effect of the deposition potential and deposition time, were optimized and electroanalytical performance of the Sb-CPE in nondeaerated solution of 0.01 M hydrochloric acid (pH 2) was compared with related bismuth powder-modified carbon paste electrode (Bi-CPE) and with in situ prepared antimony film carbon paste electrode (SbF-CPE). Favorable limits of detection were achieved; namely: 1.4 ug L?1 for Cd(II) and 0.9 ug L?1 for Pb(II). The applicability of the new electrode was demonstrated on the analysis of tap water. The Sb-CPE was preliminary tested also under chronopotentiometric stripping mode in deoxygenated solutions.
Název v anglickém jazyce
Antimony Powder-Modified Carbon Paste Electrodes for Electrochemical Stripping Determination of Trace Heavy Metals
Popis výsledku anglicky
A new type of the antimony electrode based on a carbon paste bulk-modified with antimony powder (Sb-CPE) is presented for the determination of cadmium(II) and lead(II) ions at the ug L-1 concentration level, when using SWASV or stripping chronopotentiometric protocol. Key-operational parameters, including the amount of antimony powder in the carbon paste mixture, effect of the deposition potential and deposition time, were optimized and electroanalytical performance of the Sb-CPE in nondeaerated solution of 0.01 M hydrochloric acid (pH 2) was compared with related bismuth powder-modified carbon paste electrode (Bi-CPE) and with in situ prepared antimony film carbon paste electrode (SbF-CPE). Favorable limits of detection were achieved; namely: 1.4 ug L?1 for Cd(II) and 0.9 ug L?1 for Pb(II). The applicability of the new electrode was demonstrated on the analysis of tap water. The Sb-CPE was preliminary tested also under chronopotentiometric stripping mode in deoxygenated solutions.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LC06035" target="_blank" >LC06035: Centrum biofyzikální chemie, bioelektrochemie a bioanalýzy. Nové nástroje pro genomiku, proteomiku a biomedicínu.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrochimica Acta
ISSN
0013-4686
e-ISSN
—
Svazek periodika
56
Číslo periodika v rámci svazku
19
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
6673-6677
Kód UT WoS článku
000293438600014