Antimony trioxide-modified carbon paste electrode (Sb2O3-CPE) was developed and tested in combination with square-wave anodic stripping voltammetry as a new "mercury-free" sensor for the determination of selected heavy metal ions at the low ug L-1 concentration level. Measurements were carried out using non-deaerated solutions of 0.01 M HCl (pH 2) with Cd(II) + Pb(II) as model ions. Several important experimental parameters, e.g. deposition potential, deposition time, and the concentration of hydrochloric acid were studied and optimized, when the electroanalytical performance of the Sb2O3-CPE was critically compared with bismuth trioxide-modified carbon paste electrode (Bi2O3-CPE), and with the in-situ prepared antimony film carbon paste electrode (SbF-CPE) using either 0.01 M HCl (pH 2.0) or 0.1 M CH3COOH + CH3COONa (pH 4.4) as the supporting media. In contrast to other configurations of antimony film-operated electrodes, the Sb2O3-CPE has exhibited well-defined anodic stripping signa
Název v anglickém jazyce
Electro-chemical Stripping Analysis of Selected Heavy Metals at Antimony Trioxide-Modified Carbon Paste Electrode
Popis výsledku anglicky
Antimony trioxide-modified carbon paste electrode (Sb2O3-CPE) was developed and tested in combination with square-wave anodic stripping voltammetry as a new "mercury-free" sensor for the determination of selected heavy metal ions at the low ug L-1 concentration level. Measurements were carried out using non-deaerated solutions of 0.01 M HCl (pH 2) with Cd(II) + Pb(II) as model ions. Several important experimental parameters, e.g. deposition potential, deposition time, and the concentration of hydrochloric acid were studied and optimized, when the electroanalytical performance of the Sb2O3-CPE was critically compared with bismuth trioxide-modified carbon paste electrode (Bi2O3-CPE), and with the in-situ prepared antimony film carbon paste electrode (SbF-CPE) using either 0.01 M HCl (pH 2.0) or 0.1 M CH3COOH + CH3COONa (pH 4.4) as the supporting media. In contrast to other configurations of antimony film-operated electrodes, the Sb2O3-CPE has exhibited well-defined anodic stripping signa
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Electrochemical Science
ISSN
1452-3981
e-ISSN
—
Svazek periodika
7
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CS - Srbsko a Černá Hora
Počet stran výsledku
14
Strana od-do
197-210
Kód UT WoS článku
000302723700016
EID výsledku v databázi Scopus
—