Novel Type of Carbon Nanotube Paste Electrode Modified by Sb2O3 for Square Wave Anodic Stripping Voltammetric Determination of Cd(2+)and Pb(2+)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F20%3A10419916" target="_blank" >RIV/00216208:11310/20:10419916 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=YMFN2LuJP1" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=YMFN2LuJP1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.202060137" target="_blank" >10.1002/elan.202060137</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Novel Type of Carbon Nanotube Paste Electrode Modified by Sb2O3 for Square Wave Anodic Stripping Voltammetric Determination of Cd(2+)and Pb(2+)
Popis výsledku v původním jazyce
A novel type of carbon paste electrode modified by multi-walled carbon nanotubes and antimony trioxide (Sb2O3/CNTCPE) was applied for square wave anodic stripping voltammetry (SWASV) of Cd(2+) and Pb(2+). Important parameters (deposition potential, deposition time, HCl concentration) were optimized and linear concentration dependence was obtained in the range of 10-100 ppb with LOD1.7 ppb for Cd(2+) and 1.2 ppb for Pb(2+). The practical applicability was tested on the determination of Cd(2+) and Pb(2+) in tap water. The potentiometric stripping analysis at Sb2O3/CNTCPE was tested for the determination of Cd(2+) and Pb(2+) to compare this method with SWASV.
Název v anglickém jazyce
Novel Type of Carbon Nanotube Paste Electrode Modified by Sb2O3 for Square Wave Anodic Stripping Voltammetric Determination of Cd(2+)and Pb(2+)
Popis výsledku anglicky
A novel type of carbon paste electrode modified by multi-walled carbon nanotubes and antimony trioxide (Sb2O3/CNTCPE) was applied for square wave anodic stripping voltammetry (SWASV) of Cd(2+) and Pb(2+). Important parameters (deposition potential, deposition time, HCl concentration) were optimized and linear concentration dependence was obtained in the range of 10-100 ppb with LOD1.7 ppb for Cd(2+) and 1.2 ppb for Pb(2+). The practical applicability was tested on the determination of Cd(2+) and Pb(2+) in tap water. The potentiometric stripping analysis at Sb2O3/CNTCPE was tested for the determination of Cd(2+) and Pb(2+) to compare this method with SWASV.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA20-01589S" target="_blank" >GA20-01589S: Nové strategie pro zlepšení senzorových vlastností nových elektrodových materiálů prostřednictvím jejich předúpravy či modifikace povrchu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
32
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
2260-2265
Kód UT WoS článku
000550432500001
EID výsledku v databázi Scopus
2-s2.0-85088233171