Gradient Elution in Aqueous Normal-Phase Liquid Chromatography on Hydrosilated Silica-Based Stationary Phases
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F13%3A39896310" target="_blank" >RIV/00216275:25310/13:39896310 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S002196731300366X" target="_blank" >http://www.sciencedirect.com/science/article/pii/S002196731300366X</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2013.02.059" target="_blank" >10.1016/j.chroma.2013.02.059</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Gradient Elution in Aqueous Normal-Phase Liquid Chromatography on Hydrosilated Silica-Based Stationary Phases
Popis výsledku v původním jazyce
The possibility of applying a theoretical model in the prediction of the retention of phenolic acids on hydrosilated silica, in aqueous normal phase mode was studied. The actual gradient of the aqueous component in acetonitrile may fluctuate from the pre-set program, as even the gradient-grade acetonitrile contains some water. Hence, the actual concentration of water during the gradient run is higher than pre-set by the gradient program, which leads to lower than expected sample retention. Furthermore,the actual gradient profile may be affected by an increase in water uptake on a polar column during the gradient run. These effects were investigated using the using frontal analysis method and Karl-Fischer titration, for the determination of water in the initial mobile phase, and in the column effluent. Preferential adsorption of water on the Silica hydride, Diamond hydride, UDC Cholesterol, Bidentate C-18, and Phenyl hydride columns can be described by Langmuir isotherms. At the column
Název v anglickém jazyce
Gradient Elution in Aqueous Normal-Phase Liquid Chromatography on Hydrosilated Silica-Based Stationary Phases
Popis výsledku anglicky
The possibility of applying a theoretical model in the prediction of the retention of phenolic acids on hydrosilated silica, in aqueous normal phase mode was studied. The actual gradient of the aqueous component in acetonitrile may fluctuate from the pre-set program, as even the gradient-grade acetonitrile contains some water. Hence, the actual concentration of water during the gradient run is higher than pre-set by the gradient program, which leads to lower than expected sample retention. Furthermore,the actual gradient profile may be affected by an increase in water uptake on a polar column during the gradient run. These effects were investigated using the using frontal analysis method and Karl-Fischer titration, for the determination of water in the initial mobile phase, and in the column effluent. Preferential adsorption of water on the Silica hydride, Diamond hydride, UDC Cholesterol, Bidentate C-18, and Phenyl hydride columns can be described by Langmuir isotherms. At the column
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP206%2F12%2F0398" target="_blank" >GAP206/12/0398: Dvourozměrné separace v kapalných médiích</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
—
Svazek periodika
1286
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
111-118
Kód UT WoS článku
000317156100013