Determination of Tannic Acid Using Silica Gel Modified Carbon Paste Electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F13%3A39896385" target="_blank" >RIV/00216275:25310/13:39896385 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.electrochemsci.org/papers/vol8/80709278.pdf" target="_blank" >http://www.electrochemsci.org/papers/vol8/80709278.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of Tannic Acid Using Silica Gel Modified Carbon Paste Electrode
Popis výsledku v původním jazyce
In this paper, silica gel modified carbon paste electrode (Si-gel/CPE) was used for the determination of tannic acid (TA) by anodic stripping differential pulse voltammetry (ASDPV). The influences of pH values, amount of silica gel, accumulation potential and time on the signal enhancement of TA were optimized, and a novel electrochemical method for the determination of TA was reported. The currents obtained from ASDPV measurements at optimum conditions were linearly correlated with the concentration ofTA. Calibration curve was obtained for TA concentrations in the range of 1 - 1000x10(-9) mol l(-1). The limit of detection was found to be 0.3x10(-9) mol l(-1). The results from TA measurements by Si-gel/CPE were in good agreement with those obtained from the standard spectrophotometric method.
Název v anglickém jazyce
Determination of Tannic Acid Using Silica Gel Modified Carbon Paste Electrode
Popis výsledku anglicky
In this paper, silica gel modified carbon paste electrode (Si-gel/CPE) was used for the determination of tannic acid (TA) by anodic stripping differential pulse voltammetry (ASDPV). The influences of pH values, amount of silica gel, accumulation potential and time on the signal enhancement of TA were optimized, and a novel electrochemical method for the determination of TA was reported. The currents obtained from ASDPV measurements at optimum conditions were linearly correlated with the concentration ofTA. Calibration curve was obtained for TA concentrations in the range of 1 - 1000x10(-9) mol l(-1). The limit of detection was found to be 0.3x10(-9) mol l(-1). The results from TA measurements by Si-gel/CPE were in good agreement with those obtained from the standard spectrophotometric method.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Electrochemical Science
ISSN
1452-3981
e-ISSN
—
Svazek periodika
8
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
CS - Srbsko a Černá Hora
Počet stran výsledku
9
Strana od-do
9278-9286
Kód UT WoS článku
000323547600030
EID výsledku v databázi Scopus
—