Reliability of Protonation Constants of Vildagliptin Dimers by the Regression Analysis of pH-Titration Data
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F13%3A39896417" target="_blank" >RIV/00216275:25310/13:39896417 - isvavai.cz</a>
Výsledek na webu
<a href="http://link.springer.com/article/10.2478%2Fs11532-013-0244-1" target="_blank" >http://link.springer.com/article/10.2478%2Fs11532-013-0244-1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2478/s11532-013-0244-1" target="_blank" >10.2478/s11532-013-0244-1</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Reliability of Protonation Constants of Vildagliptin Dimers by the Regression Analysis of pH-Titration Data
Popis výsledku v původním jazyce
Protonation constants of protonated monomers and dimers of the vildagliptin are determined potentiometrically. For the low concentration c (L) = 3.3 mmol dm(-3) the monomers L and LH dominate, while for a higher concentration c (L) = 6.3 mmol dm(-3) thedimers L2H2, L2H3, L2H4 and L2H are mainly present. The algorithm used has little influence on the precision of the formation constants in comparison with the reproducibility of the titration. The mixed protonation constants of vildagliptin dimers L (q)H (r) at various temperatures are determined using FBSTAC4 and HYPERQUAD regression analysis of the potentiometric titration data. The accuracy of the protonation constants log(10) beta (qr) depends on the accuracy of the group parameters. As two group parameters L (0), H (T) are ill conditioned in a model, their determination is therefore uncertain; both can significantly cause a systematic error in the estimated common parameters log(10) beta (qr) . Using various regression diagnostics
Název v anglickém jazyce
Reliability of Protonation Constants of Vildagliptin Dimers by the Regression Analysis of pH-Titration Data
Popis výsledku anglicky
Protonation constants of protonated monomers and dimers of the vildagliptin are determined potentiometrically. For the low concentration c (L) = 3.3 mmol dm(-3) the monomers L and LH dominate, while for a higher concentration c (L) = 6.3 mmol dm(-3) thedimers L2H2, L2H3, L2H4 and L2H are mainly present. The algorithm used has little influence on the precision of the formation constants in comparison with the reproducibility of the titration. The mixed protonation constants of vildagliptin dimers L (q)H (r) at various temperatures are determined using FBSTAC4 and HYPERQUAD regression analysis of the potentiometric titration data. The accuracy of the protonation constants log(10) beta (qr) depends on the accuracy of the group parameters. As two group parameters L (0), H (T) are ill conditioned in a model, their determination is therefore uncertain; both can significantly cause a systematic error in the estimated common parameters log(10) beta (qr) . Using various regression diagnostics
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Central European Journal of Chemistry
ISSN
1895-1066
e-ISSN
—
Svazek periodika
11
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
11
Strana od-do
1101-1111
Kód UT WoS článku
000318180300008
EID výsledku v databázi Scopus
—