Retention Mechanism Studies of Selected Amino Acids and Vitamin B6 on HILIC Columns with Evaporative Light Scattering Detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F13%3A39896423" target="_blank" >RIV/00216275:25310/13:39896423 - isvavai.cz</a>
Výsledek na webu
<a href="http://link.springer.com/article/10.1007%2Fs10337-013-2502-y" target="_blank" >http://link.springer.com/article/10.1007%2Fs10337-013-2502-y</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10337-013-2502-y" target="_blank" >10.1007/s10337-013-2502-y</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Retention Mechanism Studies of Selected Amino Acids and Vitamin B6 on HILIC Columns with Evaporative Light Scattering Detection
Popis výsledku v původním jazyce
The goal of the study was to investigate separation mechanism of selected "essential" amino acids (leucine, isoleucine, threonine, tryptophan, proline, and glycine) and vitamin B6 in hydrophilic interaction liquid chromatography (HILIC) with the evaporative light scattering detection. Chromatographic measurements were made on three different HILIC columns: amide-silica (TSK-gel Amide-80), amino-silica (TSK-gel NH2-100), and cross-linked diol (Luna HILIC). The retention behaviour of the analytes was investigated as a function of different binary hydro-organic mobile phases containing 10-90 % (v/v) acetonitrile. The compounds studied were separated under isocratic and gradient conditions. The best results of tested biologically active compounds separation were obtained on the TSK-gel NH2-100 column. TSK-gel NH2 column showed mixed HILIC-ion-exchange mechanism, the highest separation efficiency and better selectivity and resolution for tested analytes than the other studied column, especi
Název v anglickém jazyce
Retention Mechanism Studies of Selected Amino Acids and Vitamin B6 on HILIC Columns with Evaporative Light Scattering Detection
Popis výsledku anglicky
The goal of the study was to investigate separation mechanism of selected "essential" amino acids (leucine, isoleucine, threonine, tryptophan, proline, and glycine) and vitamin B6 in hydrophilic interaction liquid chromatography (HILIC) with the evaporative light scattering detection. Chromatographic measurements were made on three different HILIC columns: amide-silica (TSK-gel Amide-80), amino-silica (TSK-gel NH2-100), and cross-linked diol (Luna HILIC). The retention behaviour of the analytes was investigated as a function of different binary hydro-organic mobile phases containing 10-90 % (v/v) acetonitrile. The compounds studied were separated under isocratic and gradient conditions. The best results of tested biologically active compounds separation were obtained on the TSK-gel NH2-100 column. TSK-gel NH2 column showed mixed HILIC-ion-exchange mechanism, the highest separation efficiency and better selectivity and resolution for tested analytes than the other studied column, especi
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chromatographia
ISSN
0009-5893
e-ISSN
—
Svazek periodika
76
Číslo periodika v rámci svazku
15-16
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
9
Strana od-do
929-937
Kód UT WoS článku
000322388200006
EID výsledku v databázi Scopus
—