ICP-oTOF-MS ANALYSIS OF PLATINUM IN ALGAE AND HOSPITAL WASTEWATER
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F14%3A39898088" target="_blank" >RIV/00216275:25310/14:39898088 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
ICP-oTOF-MS ANALYSIS OF PLATINUM IN ALGAE AND HOSPITAL WASTEWATER
Popis výsledku v původním jazyce
The ICP-oTOF-MS (orthogonal time-of-flight inductively coupled plasma mass spectrometry) and ICP-OES (inductively coupled plasma optical emission spectrometry) methods were evaluated with regard to their possible use for determination of Pt in hospital wastewater and algae Parachlorella kessleri gained from laboratory growth experiments. A way of sample preparation of algae prior analysis was optimised. For the ICP-oTOF-MS method (internal standard Rh 10 mu g L-1), instrumental LODs (limits of detection) were obtained on isotopes Pt-194 195 196 0.0241-0.0338 mu g L-1, procedural LODs for algae samples 0.121-0.169 mg kg(-1) and for WWTP (wastewater treatment plant) samples 0.0525-0.0845 mu g L-1. The ICP-oTOF-MS method was proved to be suitable for monitoring of Pt in algae and wastewater samples. The ICP-OES (Pt 214.42 nm) procedural LOD for algae samples 2.38 mg kg(-1) (instrumental LOD 4.76 mu g L-1) did not meet concentrations in algae from growth experiments. Pt in the WWTP wastewa
Název v anglickém jazyce
ICP-oTOF-MS ANALYSIS OF PLATINUM IN ALGAE AND HOSPITAL WASTEWATER
Popis výsledku anglicky
The ICP-oTOF-MS (orthogonal time-of-flight inductively coupled plasma mass spectrometry) and ICP-OES (inductively coupled plasma optical emission spectrometry) methods were evaluated with regard to their possible use for determination of Pt in hospital wastewater and algae Parachlorella kessleri gained from laboratory growth experiments. A way of sample preparation of algae prior analysis was optimised. For the ICP-oTOF-MS method (internal standard Rh 10 mu g L-1), instrumental LODs (limits of detection) were obtained on isotopes Pt-194 195 196 0.0241-0.0338 mu g L-1, procedural LODs for algae samples 0.121-0.169 mg kg(-1) and for WWTP (wastewater treatment plant) samples 0.0525-0.0845 mu g L-1. The ICP-oTOF-MS method was proved to be suitable for monitoring of Pt in algae and wastewater samples. The ICP-OES (Pt 214.42 nm) procedural LOD for algae samples 2.38 mg kg(-1) (instrumental LOD 4.76 mu g L-1) did not meet concentrations in algae from growth experiments. Pt in the WWTP wastewa
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemické listy
ISSN
0009-2770
e-ISSN
—
Svazek periodika
108
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
"S154"-"S159"
Kód UT WoS článku
000346508500001
EID výsledku v databázi Scopus
—