Popis výsledku v původním jazyce
Quantitative determination of the serum level of human epididymis protein 4 (HE4), a tumor marker for ovarian carcinoma, has come to the fore of interest mainly due to the possibility for its detection in early stages of the disease when the sensing of other biomarkers is limited. We present a simple ELISA based approach for rapid HE4 detection including its immunomagnetic capturing accompanied by sensitive electrochemical detection of the electroactive product formed after enzymatic conversion of the substrate by alkaline phosphatase used as a label of anti-HE4 IgG. The proposed immunosensor offers stability in time and due to excellent limit of detection at 6.8 fM HE4, and limit of quantification of 23 fM meets the requirements for the early detection of this biomarker.
Název v anglickém jazyce
Alkaline phosphatase labeled antibody-based electrochemical biosensor for sensitive HE4 tumor marker detection
Popis výsledku anglicky
Quantitative determination of the serum level of human epididymis protein 4 (HE4), a tumor marker for ovarian carcinoma, has come to the fore of interest mainly due to the possibility for its detection in early stages of the disease when the sensing of other biomarkers is limited. We present a simple ELISA based approach for rapid HE4 detection including its immunomagnetic capturing accompanied by sensitive electrochemical detection of the electroactive product formed after enzymatic conversion of the substrate by alkaline phosphatase used as a label of anti-HE4 IgG. The proposed immunosensor offers stability in time and due to excellent limit of detection at 6.8 fM HE4, and limit of quantification of 23 fM meets the requirements for the early detection of this biomarker.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP206%2F12%2F0381" target="_blank" >GAP206/12/0381: Vývoj ultrasensitivních elektrochemických imunosenzorů pro včasnou detekci klinicky významných biomarkerů maligních onemocnění</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrochemistry Communications
ISSN
1388-2481
e-ISSN
—
Svazek periodika
59
Číslo periodika v rámci svazku
October
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
4
Strana od-do
1-4
Kód UT WoS článku
000361251100001
EID výsledku v databázi Scopus
—