Green electrochemical sensors based on boron-doped diamond and silver amalgam for sensitive voltammetric determination of herbicide metamitron
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F15%3A39900146" target="_blank" >RIV/00216275:25310/15:39900146 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s00706-014-1372-9" target="_blank" >http://dx.doi.org/10.1007/s00706-014-1372-9</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00706-014-1372-9" target="_blank" >10.1007/s00706-014-1372-9</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Green electrochemical sensors based on boron-doped diamond and silver amalgam for sensitive voltammetric determination of herbicide metamitron
Popis výsledku v původním jazyce
Novel sensitive voltammetric methods for determination of herbicide metamitron were developed using polished and mercury meniscus-modi?ed silver solid amalgam electrode (p-, m-AgSAE) and boron-doped diamond electrode (BDDE). It was found that metamitronyields one analytically utilizable reduction (AgSAEs) and one oxidation (BDDE) signal. All three tested working electrodes connected to different voltammetric techniques were found to be appropriate for the analysis of the herbicide. The optimum conditions for detamitron determination were ascertained in Britton-Robinson buffer solution of pH 2.0 (m-AgSAE, BDDE) and in 0.05 mol dm-3 H2SO4 (p-AgSAE), respectively, with the limits of detection 3.6 9 10-8 mol dm-3 (m-AgSAE), 1.0 9 10-7 mol dm-3 (p-AgSAE),and 1.2 9 10-6 mol dm-3 (BDDE). Calculated values of relative standard deviations of repeated determinations (n = 5) in various concentration levels of metamitron did not exceed 5 % for either of the tested electrodes. Finally, practical
Název v anglickém jazyce
Green electrochemical sensors based on boron-doped diamond and silver amalgam for sensitive voltammetric determination of herbicide metamitron
Popis výsledku anglicky
Novel sensitive voltammetric methods for determination of herbicide metamitron were developed using polished and mercury meniscus-modi?ed silver solid amalgam electrode (p-, m-AgSAE) and boron-doped diamond electrode (BDDE). It was found that metamitronyields one analytically utilizable reduction (AgSAEs) and one oxidation (BDDE) signal. All three tested working electrodes connected to different voltammetric techniques were found to be appropriate for the analysis of the herbicide. The optimum conditions for detamitron determination were ascertained in Britton-Robinson buffer solution of pH 2.0 (m-AgSAE, BDDE) and in 0.05 mol dm-3 H2SO4 (p-AgSAE), respectively, with the limits of detection 3.6 9 10-8 mol dm-3 (m-AgSAE), 1.0 9 10-7 mol dm-3 (p-AgSAE),and 1.2 9 10-6 mol dm-3 (BDDE). Calculated values of relative standard deviations of repeated determinations (n = 5) in various concentration levels of metamitron did not exceed 5 % for either of the tested electrodes. Finally, practical
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.30.0021" target="_blank" >EE2.3.30.0021: Posílení excelentních týmů výzkumu a vývoje na Univerzitě Pardubice</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Monatshefte fur Chemie
ISSN
0026-9247
e-ISSN
—
Svazek periodika
146
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
11
Strana od-do
795-805
Kód UT WoS článku
000353219700009
EID výsledku v databázi Scopus
—