Pharmaceuticals belong to the group of organic compounds that may adversely affect aquatic ecosystems. Although the detected amount is relatively low (in the order of ng/l up to tens of mg/l), by their nature pharmaceuticals have a strong biological effect on non-target organisms, even at these low concentrations. For ibuprofen was observed toxic effect on both the lower organisms (D.magna H. attenuata) and plants (L. minor) or fish (O. latipes). Similar effects were found with paracetamol. Drugs were from model water samples removed by heterogeneous photocatalysis, wherein on the catalyst surface the radiation produces oxidiser causes destruction of drug. As the catalyst used was 0.5 g/l titanium dioxide (TiO2, Precheza a.s.). As a source of UV radiation was used UV lamp (Helling) with absorbance maxima at 365 nm. At the same time the various concentrations of hydrogen peroxide (H2O2) or at different pH values was determined. Samples were analyzed by high performance liquid chromatogr
Název v anglickém jazyce
Removal of selected pharmaceuticals by heterogeneous photocatalysis
Popis výsledku anglicky
Pharmaceuticals belong to the group of organic compounds that may adversely affect aquatic ecosystems. Although the detected amount is relatively low (in the order of ng/l up to tens of mg/l), by their nature pharmaceuticals have a strong biological effect on non-target organisms, even at these low concentrations. For ibuprofen was observed toxic effect on both the lower organisms (D.magna H. attenuata) and plants (L. minor) or fish (O. latipes). Similar effects were found with paracetamol. Drugs were from model water samples removed by heterogeneous photocatalysis, wherein on the catalyst surface the radiation produces oxidiser causes destruction of drug. As the catalyst used was 0.5 g/l titanium dioxide (TiO2, Precheza a.s.). As a source of UV radiation was used UV lamp (Helling) with absorbance maxima at 365 nm. At the same time the various concentrations of hydrogen peroxide (H2O2) or at different pH values was determined. Samples were analyzed by high performance liquid chromatogr
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
DJ - Znečištění a kontrola vody
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 3rd International Conference on Chemical Technology
ISBN
978-80-86238-79-1
ISSN
2336-811X
e-ISSN
—
Počet stran výsledku
5
Strana od-do
370-374
Název nakladatele
Česká společnost průmyslové chemie
Místo vydání
Praha
Místo konání akce
Mikulov
Datum konání akce
13. 4. 2015