Selection of a Bismuth Film Electrode for Simultaneous Voltammetric Detection of Heavy Metals as the Final Step of an Immunoassay with the Quantum Dots
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F16%3A39901166" target="_blank" >RIV/00216275:25310/16:39901166 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Selection of a Bismuth Film Electrode for Simultaneous Voltammetric Detection of Heavy Metals as the Final Step of an Immunoassay with the Quantum Dots
Popis výsledku v původním jazyce
Solid glassy carbon (GCE), metal disk, and commercial screen-printed electrodes (SPEs) were tested as suitable substrate(s) for deposition of bismuth films. The respective bismuth film electrodes were then used for the simultaneous voltammetric detection of selected heavy metals that had simulated the dissolved quantum dots of the immunoassays known as QLISA. According to the results obtained, it has been found that selected commercial SPEs are not suitable electrode substrates due to a parasitic anodic peak at DRP-150 and DRP-250AT, having significantly increased the background current under repetition of the same measurement at DRP-110, as well as decomposition of the supporting electrolyte at highly negative potentials at DRP-250BT. Unlike metal disk electrodes, GCE coated with thin bismuth film was applicable up to -1.5 V.
Název v anglickém jazyce
Selection of a Bismuth Film Electrode for Simultaneous Voltammetric Detection of Heavy Metals as the Final Step of an Immunoassay with the Quantum Dots
Popis výsledku anglicky
Solid glassy carbon (GCE), metal disk, and commercial screen-printed electrodes (SPEs) were tested as suitable substrate(s) for deposition of bismuth films. The respective bismuth film electrodes were then used for the simultaneous voltammetric detection of selected heavy metals that had simulated the dissolved quantum dots of the immunoassays known as QLISA. According to the results obtained, it has been found that selected commercial SPEs are not suitable electrode substrates due to a parasitic anodic peak at DRP-150 and DRP-250AT, having significantly increased the background current under repetition of the same measurement at DRP-110, as well as decomposition of the supporting electrolyte at highly negative potentials at DRP-250BT. Unlike metal disk electrodes, GCE coated with thin bismuth film was applicable up to -1.5 V.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA15-16549S" target="_blank" >GA15-16549S: Vývoj ultrasensitivní imunomagnetické metody s kvantovými tečkami pro simultánní elektrochemickou detekci nádorových markerů.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XXXVI Moderní elektrochemické metody
ISBN
978-80-905221-4-5
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
228-231
Název nakladatele
BEST Servis
Místo vydání
Ústí nad Labem
Místo konání akce
Jetřichovice
Datum konání akce
23. 5. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000389898200052