Comparison of various bismuth film electrodes in simultaneous electrochemical detection of heavy metals for application in quantum dot-linked immunoassays
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F17%3A39910446" target="_blank" >RIV/00216275:25310/17:39910446 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s00706-016-1901-9" target="_blank" >http://dx.doi.org/10.1007/s00706-016-1901-9</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00706-016-1901-9" target="_blank" >10.1007/s00706-016-1901-9</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of various bismuth film electrodes in simultaneous electrochemical detection of heavy metals for application in quantum dot-linked immunoassays
Popis výsledku v původním jazyce
Various electrode materials commonly used in electroanalysis were tested in preparation of respective bismuth film electrodes and compared in simultaneous electrochemical detection of heavy metals, simulating dissolved quantum dots used as labels of antibodies in quantum dot-linked immunosorbent assays. According to results obtained during voltammetric measurements, it can be concluded that selected commercial screen-printed electrodes showed many significant drawbacks which are described in detail. Contrary to the gold disk electrode, conventional glassy carbon electrode coated with thin bismuth film was applicable up to -1.5 V without the need to use very high content of bismuth in supporting electrolyte. Moreover, significant interactions among present metals were observed during their electrochemical stripping analysis, especially in presence of copper and silver.
Název v anglickém jazyce
Comparison of various bismuth film electrodes in simultaneous electrochemical detection of heavy metals for application in quantum dot-linked immunoassays
Popis výsledku anglicky
Various electrode materials commonly used in electroanalysis were tested in preparation of respective bismuth film electrodes and compared in simultaneous electrochemical detection of heavy metals, simulating dissolved quantum dots used as labels of antibodies in quantum dot-linked immunosorbent assays. According to results obtained during voltammetric measurements, it can be concluded that selected commercial screen-printed electrodes showed many significant drawbacks which are described in detail. Contrary to the gold disk electrode, conventional glassy carbon electrode coated with thin bismuth film was applicable up to -1.5 V without the need to use very high content of bismuth in supporting electrolyte. Moreover, significant interactions among present metals were observed during their electrochemical stripping analysis, especially in presence of copper and silver.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA15-16549S" target="_blank" >GA15-16549S: Vývoj ultrasensitivní imunomagnetické metody s kvantovými tečkami pro simultánní elektrochemickou detekci nádorových markerů.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Monatshefte fur Chemie
ISSN
0026-9247
e-ISSN
—
Svazek periodika
142
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
6
Strana od-do
505-510
Kód UT WoS článku
000396528600015
EID výsledku v databázi Scopus
—