Voltammetric Analysis of Herbicide Picloram on the Silver Solid Amalgam Electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F16%3A39901438" target="_blank" >RIV/00216275:25310/16:39901438 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1080/00032719.2014.979294" target="_blank" >http://dx.doi.org/10.1080/00032719.2014.979294</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/00032719.2014.979294" target="_blank" >10.1080/00032719.2014.979294</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric Analysis of Herbicide Picloram on the Silver Solid Amalgam Electrode
Popis výsledku v původním jazyce
A silver solid amalgam electrode was employed for the first time for the determination of the pyridine herbicide picloram. The voltammetric behavior of this herbicide was studied using cyclic, direct current, and differential pulse voltammetry on the mercury meniscus modified silver solid amalgam electrode. All results were compared with those achieved on the classic hanging mercury drop electrode. One reduction signal, which was suitable for analytical purposes, was recorded on the amalgam electrode after addition of picloram. The current response of the herbicide increased linearly in the concentration range from 1x10(-7) to 8x10(-5)moles per liter, and a limit of detection of 8.78x10(-8)moles per liter was obtained using differential pulse voltammetry under the optimized conditions. The selectivity and applicability of the voltammetric technique was verified by an interference study and analysis of fortified environmental samples with excellent recoveries: 100.0%(tap water), 100.5% (dam water), and 95.0% (river water).
Název v anglickém jazyce
Voltammetric Analysis of Herbicide Picloram on the Silver Solid Amalgam Electrode
Popis výsledku anglicky
A silver solid amalgam electrode was employed for the first time for the determination of the pyridine herbicide picloram. The voltammetric behavior of this herbicide was studied using cyclic, direct current, and differential pulse voltammetry on the mercury meniscus modified silver solid amalgam electrode. All results were compared with those achieved on the classic hanging mercury drop electrode. One reduction signal, which was suitable for analytical purposes, was recorded on the amalgam electrode after addition of picloram. The current response of the herbicide increased linearly in the concentration range from 1x10(-7) to 8x10(-5)moles per liter, and a limit of detection of 8.78x10(-8)moles per liter was obtained using differential pulse voltammetry under the optimized conditions. The selectivity and applicability of the voltammetric technique was verified by an interference study and analysis of fortified environmental samples with excellent recoveries: 100.0%(tap water), 100.5% (dam water), and 95.0% (river water).
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Letters
ISSN
0003-2719
e-ISSN
—
Svazek periodika
49
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
18
Strana od-do
19-36
Kód UT WoS článku
000363048900003
EID výsledku v databázi Scopus
—