Comparative Study on Electroanalysis of Fenthion Using Silver Amalgam Film Electrode and Glassy Carbon Electrode Modified with Reduced Graphene Oxide
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F17%3A39911328" target="_blank" >RIV/00216275:25310/17:39911328 - isvavai.cz</a>
Výsledek na webu
<a href="http://onlinelibrary.wiley.com/doi/10.1002/elan.201600710/abstract" target="_blank" >http://onlinelibrary.wiley.com/doi/10.1002/elan.201600710/abstract</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201600710" target="_blank" >10.1002/elan.201600710</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparative Study on Electroanalysis of Fenthion Using Silver Amalgam Film Electrode and Glassy Carbon Electrode Modified with Reduced Graphene Oxide
Popis výsledku v původním jazyce
Oxidation and reduction processes of the insecticide fenthion was comparatively investigated at a reduced graphene oxide modified glassy carbon electrode (RGO-GCE) and a cyclic renewable silver amalgam film electrode (Hg(Ag)FE) using square wave stripping voltammetry (SWSV). The influence of pH and SW parameters was investigated. The linear concentration ranges were found to be 1 x 10(-6) - 2 x 10(-5) and 1 x 10(-7) - 2 x 10(-5) mol L-1 for Hg(Ag)FE and RGO-GCE, respectively. The detection and quantification limits were calculated as 1.3 x 10(-7) and 4.5 x 10(-7) mol L-1 for Hg(Ag)FE and 7.6 x 10(-9) and 2.5 x 10(-8) molL(-1) for RGO-GCE. Both of the developed electroanalytical methods offer rapid and simple detection of fenthion and were used on spiked tap and river water and apple juice samples. Scanning electron microscopy was used for RGO-GCE surface characterization.
Název v anglickém jazyce
Comparative Study on Electroanalysis of Fenthion Using Silver Amalgam Film Electrode and Glassy Carbon Electrode Modified with Reduced Graphene Oxide
Popis výsledku anglicky
Oxidation and reduction processes of the insecticide fenthion was comparatively investigated at a reduced graphene oxide modified glassy carbon electrode (RGO-GCE) and a cyclic renewable silver amalgam film electrode (Hg(Ag)FE) using square wave stripping voltammetry (SWSV). The influence of pH and SW parameters was investigated. The linear concentration ranges were found to be 1 x 10(-6) - 2 x 10(-5) and 1 x 10(-7) - 2 x 10(-5) mol L-1 for Hg(Ag)FE and RGO-GCE, respectively. The detection and quantification limits were calculated as 1.3 x 10(-7) and 4.5 x 10(-7) mol L-1 for Hg(Ag)FE and 7.6 x 10(-9) and 2.5 x 10(-8) molL(-1) for RGO-GCE. Both of the developed electroanalytical methods offer rapid and simple detection of fenthion and were used on spiked tap and river water and apple juice samples. Scanning electron microscopy was used for RGO-GCE surface characterization.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
29
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
7
Strana od-do
1154-1160
Kód UT WoS článku
000398850400030
EID výsledku v databázi Scopus
—