ANALYSIS OF VOLATILE ORGANIC COMPOUNDS IN ROSE PETALS USING HEADSPACE SOLIDPHASE MICROEXTRACTION COUPLED TO GAS CHROMATOGRAPHY-MASS SPECTROMETRY
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F17%3A39911610" target="_blank" >RIV/00216275:25310/17:39911610 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
ANALYSIS OF VOLATILE ORGANIC COMPOUNDS IN ROSE PETALS USING HEADSPACE SOLIDPHASE MICROEXTRACTION COUPLED TO GAS CHROMATOGRAPHY-MASS SPECTROMETRY
Popis výsledku v původním jazyce
Headspace solid-phase microextraction coupled to gas chromatography and mass spectrometry (HS-SPME-GC/MS) has been optimised for the analysis of volatile compounds in six samples of rose petals (Rosa Mariyo, Rose Tara, Rosa Rhodos, Rosa Sudoku, Rosa Deep Purple, Rosa Tacazzi). Volatiles from roses were extracted using a SPME fibre by carrying out the subsequent separation and identification by comparison of their mass spectra with mass spectra libraries and retention indexes. Several factors influencing the SPME were taken into account; namely, extraction time, extraction temperature and the sample weight. The optimal parameters of the extraction of volatile compounds were obtained based on statistical evaluation; the most suitable conditions being the extraction time of 60 min., the extraction temperature of 90 °C and the sample weight of 0.7 g.
Název v anglickém jazyce
ANALYSIS OF VOLATILE ORGANIC COMPOUNDS IN ROSE PETALS USING HEADSPACE SOLIDPHASE MICROEXTRACTION COUPLED TO GAS CHROMATOGRAPHY-MASS SPECTROMETRY
Popis výsledku anglicky
Headspace solid-phase microextraction coupled to gas chromatography and mass spectrometry (HS-SPME-GC/MS) has been optimised for the analysis of volatile compounds in six samples of rose petals (Rosa Mariyo, Rose Tara, Rosa Rhodos, Rosa Sudoku, Rosa Deep Purple, Rosa Tacazzi). Volatiles from roses were extracted using a SPME fibre by carrying out the subsequent separation and identification by comparison of their mass spectra with mass spectra libraries and retention indexes. Several factors influencing the SPME were taken into account; namely, extraction time, extraction temperature and the sample weight. The optimal parameters of the extraction of volatile compounds were obtained based on statistical evaluation; the most suitable conditions being the extraction time of 60 min., the extraction temperature of 90 °C and the sample weight of 0.7 g.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scientific Papers of the University of Pardubice, Series A, Faculty of Chemical Technology
ISSN
1211-5541
e-ISSN
—
Svazek periodika
23
Číslo periodika v rámci svazku
květen
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
13
Strana od-do
71-83
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—