Effect of surfactants in simultaneous electroanalytical determination of biologically active nitrogen-containing heterocycles
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F18%3A39912944" target="_blank" >RIV/00216275:25310/18:39912944 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of surfactants in simultaneous electroanalytical determination of biologically active nitrogen-containing heterocycles
Popis výsledku v původním jazyce
This electrochemical study is focused on selection of suitable surfactant for simultaneous voltammetric determination of biologically active nitrogen-containing heterocycles. Herein, xanthine alkaloid caffeine (CA) and pyridoxine (vitamin B6; VB6) were chosen as typical illustrative analytes. This work represents an initial step in the development of sophisticated electroanalytical method. Glassy carbon electrode and two of its modifications were tested in model samples of the Britton-Robinson pH 4.0 buffer, which contained always 100 μM CA and 100 μM VB6 and one of the surfactants tested, either nonionic Triton X-100, anionic sodium dodecyl sulfate, or cationic cetylpyridinium chloride or 1,3-idecyl-2-methylimidazolium chloride. The results show that the presence of surfactants contributes to improving the reproducibility of voltammetric measurements, but unfortunately does not cause any peak position differentiation.
Název v anglickém jazyce
Effect of surfactants in simultaneous electroanalytical determination of biologically active nitrogen-containing heterocycles
Popis výsledku anglicky
This electrochemical study is focused on selection of suitable surfactant for simultaneous voltammetric determination of biologically active nitrogen-containing heterocycles. Herein, xanthine alkaloid caffeine (CA) and pyridoxine (vitamin B6; VB6) were chosen as typical illustrative analytes. This work represents an initial step in the development of sophisticated electroanalytical method. Glassy carbon electrode and two of its modifications were tested in model samples of the Britton-Robinson pH 4.0 buffer, which contained always 100 μM CA and 100 μM VB6 and one of the surfactants tested, either nonionic Triton X-100, anionic sodium dodecyl sulfate, or cationic cetylpyridinium chloride or 1,3-idecyl-2-methylimidazolium chloride. The results show that the presence of surfactants contributes to improving the reproducibility of voltammetric measurements, but unfortunately does not cause any peak position differentiation.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Monitorování cizorodých látek v životním prostředí XX. : sborník ze semináře s mezinárodní účastí
ISBN
978-80-7560-154-4
ISSN
—
e-ISSN
neuvedeno
Počet stran výsledku
6
Strana od-do
45-50
Název nakladatele
Univerzita Pardubice
Místo vydání
Pardubice
Místo konání akce
Ovčárna pod Pradědem
Datum konání akce
25. 4. 2018
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—