Simultaneous Determination of Caffeine and Pyridoxine in Energy Drinks using Differential Pulse Voltammetry at Glassy Carbon Electrode Modified with Nafion (R)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F19%3A39914606" target="_blank" >RIV/00216275:25310/19:39914606 - isvavai.cz</a>
Výsledek na webu
<a href="https://onlinelibrary.wiley.com/doi/full/10.1002/elan.201800646" target="_blank" >https://onlinelibrary.wiley.com/doi/full/10.1002/elan.201800646</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201800646" target="_blank" >10.1002/elan.201800646</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Simultaneous Determination of Caffeine and Pyridoxine in Energy Drinks using Differential Pulse Voltammetry at Glassy Carbon Electrode Modified with Nafion (R)
Popis výsledku v původním jazyce
A new voltammetric method for simultaneous determination of caffeine and pyridoxine present in different types of commercial energy drinks has been developed. This electroanalytical method is based on anodic oxidation of these biologically active nitrogen-containing heterocycles at glassy carbon electrode covered with thin layer of sulfonated fluoropolymer Nafion® using differential pulse voltammetry in 0.1 M Britton-Robinson buffer of pH 4.5 at potential step 5 mV, potential amplitude 70 mV, and scan rate 50 mV/s. Linear ranges for caffeine and pyridoxine determination were 63.1-600 µM and 7.5-200 µM with the detection limits of 18.9 and 2.2 µM, respectively. It was validated using high-performance liquid chromatography with spectrophotometric detection. Obtained results have shown that voltammetric approach is very simple and low-cost analytical method which can be used for routine determination of caffeine and pyridoxine in energy drinks.
Název v anglickém jazyce
Simultaneous Determination of Caffeine and Pyridoxine in Energy Drinks using Differential Pulse Voltammetry at Glassy Carbon Electrode Modified with Nafion (R)
Popis výsledku anglicky
A new voltammetric method for simultaneous determination of caffeine and pyridoxine present in different types of commercial energy drinks has been developed. This electroanalytical method is based on anodic oxidation of these biologically active nitrogen-containing heterocycles at glassy carbon electrode covered with thin layer of sulfonated fluoropolymer Nafion® using differential pulse voltammetry in 0.1 M Britton-Robinson buffer of pH 4.5 at potential step 5 mV, potential amplitude 70 mV, and scan rate 50 mV/s. Linear ranges for caffeine and pyridoxine determination were 63.1-600 µM and 7.5-200 µM with the detection limits of 18.9 and 2.2 µM, respectively. It was validated using high-performance liquid chromatography with spectrophotometric detection. Obtained results have shown that voltammetric approach is very simple and low-cost analytical method which can be used for routine determination of caffeine and pyridoxine in energy drinks.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
31
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
1511-1516
Kód UT WoS článku
000479081100012