Molar mass distribution by size exclusion chromatography: Comparison of multi-angle light scattering and universal calibration
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F19%3A39914778" target="_blank" >RIV/00216275:25310/19:39914778 - isvavai.cz</a>
Výsledek na webu
<a href="https://onlinelibrary.wiley.com/doi/full/10.1002/app.47561" target="_blank" >https://onlinelibrary.wiley.com/doi/full/10.1002/app.47561</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/app.47561" target="_blank" >10.1002/app.47561</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Molar mass distribution by size exclusion chromatography: Comparison of multi-angle light scattering and universal calibration
Popis výsledku v původním jazyce
Series of polymers of various molar mass, chemical composition, and molecular architecture was analyzed by size exclusion chromatography (SEC) coupled with a multi-angle light scattering (MALS) photometer and an online viscometer. The molar mass averages were determined from the signal of MALS or calculated from the intrinsic viscosity and universal calibration. The comparison of the obtained results showed significant differences between the two methods. The MALS detection was shown to be more accurate for the determination of the weight-average molar mass and less vulnerable to the spreading of polymer peak by band broadening. The universal calibration can yield more accurate estimation of the number-average molar mass of branched polymers. It is also significantly more accurate for the characterization of fluorescent polymers than MALS with a regular laser of 660 nm. (c) 2019 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2019, 136, 47561.
Název v anglickém jazyce
Molar mass distribution by size exclusion chromatography: Comparison of multi-angle light scattering and universal calibration
Popis výsledku anglicky
Series of polymers of various molar mass, chemical composition, and molecular architecture was analyzed by size exclusion chromatography (SEC) coupled with a multi-angle light scattering (MALS) photometer and an online viscometer. The molar mass averages were determined from the signal of MALS or calculated from the intrinsic viscosity and universal calibration. The comparison of the obtained results showed significant differences between the two methods. The MALS detection was shown to be more accurate for the determination of the weight-average molar mass and less vulnerable to the spreading of polymer peak by band broadening. The universal calibration can yield more accurate estimation of the number-average molar mass of branched polymers. It is also significantly more accurate for the characterization of fluorescent polymers than MALS with a regular laser of 660 nm. (c) 2019 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2019, 136, 47561.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10404 - Polymer science
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Applied Polymer Science
ISSN
0021-8995
e-ISSN
—
Svazek periodika
136
Číslo periodika v rámci svazku
21
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
"47561-1"-"47561-10"
Kód UT WoS článku
000459320700019
EID výsledku v databázi Scopus
—