Popis výsledku v původním jazyce
This scientific study describes a comparison of various working electrode materials and organic solvents in simultaneous voltammetry determination of retinyl acetate (or retinyl palmitate) and α- tocopheryl acetate based on their anodic oxidation using square wave voltammetry. It has been found that the glassy carbon is the electrode material of choice providing the most favourable current responses and well developed peak(s) in 99.7% acetone with 0.1 mol L-1 LiClO4. It can be assumed that anodic oxidation of these two analysts could be utilized to develop a simple and rapid simultaneous voltammetry method for determination in cosmetic products.
Název v anglickém jazyce
Optimization of working conditions in voltammetric simultaneous determination of retinyl acetate and α-tocopheryl acetate
Popis výsledku anglicky
This scientific study describes a comparison of various working electrode materials and organic solvents in simultaneous voltammetry determination of retinyl acetate (or retinyl palmitate) and α- tocopheryl acetate based on their anodic oxidation using square wave voltammetry. It has been found that the glassy carbon is the electrode material of choice providing the most favourable current responses and well developed peak(s) in 99.7% acetone with 0.1 mol L-1 LiClO4. It can be assumed that anodic oxidation of these two analysts could be utilized to develop a simple and rapid simultaneous voltammetry method for determination in cosmetic products.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Bezpečnosť a kontrola potravín : zborník prác z XVII. vedeckej konferencie s medzinárodnou účasťou online
ISBN
978-80-552-2168-7
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
99-104
Název nakladatele
Slovenská poľnohospodárská univerzita v Nitre
Místo vydání
Nitra
Místo konání akce
Piešťany
Datum konání akce
26. 3. 2020
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—