Ultrahigh-performance supercritical fluid chromatography - mass spectrometry for the qualitative analysis of metabolites covering a large polarity range
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F22%3A39918845" target="_blank" >RIV/00216275:25310/22:39918845 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0021967322000309" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0021967322000309</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2022.462832" target="_blank" >10.1016/j.chroma.2022.462832</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ultrahigh-performance supercritical fluid chromatography - mass spectrometry for the qualitative analysis of metabolites covering a large polarity range
Popis výsledku v původním jazyce
The applicability of ultrahigh-performance supercritical fluid chromatography coupled with mass spectrometry (UHPSFC/MS) for the qualitative analysis of metabolites with a wide polarity range (log P: -3.89-18.95) was evaluated using a representative set of 78 standards belonging to nucleosides, biogenic amines, carbohydrates, amino acids, and lipids. The effects of the gradient shape and the percentage of water (1, 2, and 5%) were investigated on the Viridis BEH column. The screening of eight stationary phases was performed for columns with different interaction sites, such as hydrogen bonding, hydrophobic, pi-pi, or anionic exchange type interactions. The highest number of compounds (67) of the set studied was detected on the Torus Diol column, which provided a resolution parameter of 39. The DEA column had the second best performance with 58 detected standards and the resolution parameter of 54. The overall performance of other parameters, such as selectivity, peak height, peak area, retention time stability, asymmetry factor, and mass accuracy, led to the selection of the Diol column for the final method. The comparison of additives showed that ammonium acetate gave a superior sensitivity over ammonium formate. Moreover, the influence of the ion source on the ionization efficiency was studied by employing atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI). The results proved the complementarity of both ionization techniques, but also the superior ionization capacity of the ESI source in the negative ion mode, for which 53% of the analytes were detected compared to only 7% for the APCI source. Finally, optimized analytical conditions were applied to the analysis of a pooled human plasma sample. 44 compounds from the preselected set were detected in human plasma using ESI-UHPSFC/MS in MS E mode considering both ionization modes. (C) 2022 Published by Elsevier B.V.
Název v anglickém jazyce
Ultrahigh-performance supercritical fluid chromatography - mass spectrometry for the qualitative analysis of metabolites covering a large polarity range
Popis výsledku anglicky
The applicability of ultrahigh-performance supercritical fluid chromatography coupled with mass spectrometry (UHPSFC/MS) for the qualitative analysis of metabolites with a wide polarity range (log P: -3.89-18.95) was evaluated using a representative set of 78 standards belonging to nucleosides, biogenic amines, carbohydrates, amino acids, and lipids. The effects of the gradient shape and the percentage of water (1, 2, and 5%) were investigated on the Viridis BEH column. The screening of eight stationary phases was performed for columns with different interaction sites, such as hydrogen bonding, hydrophobic, pi-pi, or anionic exchange type interactions. The highest number of compounds (67) of the set studied was detected on the Torus Diol column, which provided a resolution parameter of 39. The DEA column had the second best performance with 58 detected standards and the resolution parameter of 54. The overall performance of other parameters, such as selectivity, peak height, peak area, retention time stability, asymmetry factor, and mass accuracy, led to the selection of the Diol column for the final method. The comparison of additives showed that ammonium acetate gave a superior sensitivity over ammonium formate. Moreover, the influence of the ion source on the ionization efficiency was studied by employing atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI). The results proved the complementarity of both ionization techniques, but also the superior ionization capacity of the ESI source in the negative ion mode, for which 53% of the analytes were detected compared to only 7% for the APCI source. Finally, optimized analytical conditions were applied to the analysis of a pooled human plasma sample. 44 compounds from the preselected set were detected in human plasma using ESI-UHPSFC/MS in MS E mode considering both ionization modes. (C) 2022 Published by Elsevier B.V.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GJ20-23290Y" target="_blank" >GJ20-23290Y: Absolutní kvantifikace iontových a polárních biomolekul s využitím superkritické fluidní chromatografie ve spojení s hmotnostní spektrometrií</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
1873-3778
Svazek periodika
1665
Číslo periodika v rámci svazku
February
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
12
Strana od-do
462832
Kód UT WoS článku
000766209700005
EID výsledku v databázi Scopus
2-s2.0-85123050001