A Reversed-Phase High-Performance Liquid Chromatographic/Mass Spectrometric (RP-HPLC/MS-SIM) Method for Separation of 4-methylimidazole and 2-acetyl-4-(1,2,3,4-tetrahydroxybutyl)imidazole at pg levels
Popis výsledku v původním jazyce
A high-performance liquid chromatographic/mass spectrometric method (HPLC/MS) has been developed to determine both 4-methylimidazole (4MeI) and 2-acetyl-4-(1,2,3,4-tetrahydroxybutyl)imidazole (THI) in one run. Among three sorbents tested, the best peak shape of 4MeI was achieved on a reversed phase MetaChem Polaris C18-A at pH 9.5. The sensitivity and the range of UV detection at 215 and 290 nm for 4MeI and THI, respectively, were compared to the parameters achieved by the electrospray ionization mass spectrometric (ESI/MS) detection in the presence of 5 mmol.L-1 ammonium hydroxide using selected ion-monitoring (SIM) mode. The on-column limits of detection were 0.147 ng of 4MeI and 0.084 ng of THI using UV detection and 1 pg of 4MeI and 3 pg of THI using ESI/MS detection, respectively. The effect of both ammonium ion concentration and energy of fragmentation on 4MeI and THI ionization is discussed. The method could be applied for a fast and sensitive determination of 4MeI and THI in di
Název v anglickém jazyce
A Reversed-Phase High-Performance Liquid Chromatographic/Mass Spectrometric (RP-HPLC/MS-SIM) Method for Separation of 4-methylimidazole and 2-acetyl-4-(1,2,3,4-tetrahydroxybutyl)imidazole at pg levels
Popis výsledku anglicky
A high-performance liquid chromatographic/mass spectrometric method (HPLC/MS) has been developed to determine both 4-methylimidazole (4MeI) and 2-acetyl-4-(1,2,3,4-tetrahydroxybutyl)imidazole (THI) in one run. Among three sorbents tested, the best peak shape of 4MeI was achieved on a reversed phase MetaChem Polaris C18-A at pH 9.5. The sensitivity and the range of UV detection at 215 and 290 nm for 4MeI and THI, respectively, were compared to the parameters achieved by the electrospray ionization mass spectrometric (ESI/MS) detection in the presence of 5 mmol.L-1 ammonium hydroxide using selected ion-monitoring (SIM) mode. The on-column limits of detection were 0.147 ng of 4MeI and 0.084 ng of THI using UV detection and 1 pg of 4MeI and 3 pg of THI using ESI/MS detection, respectively. The effect of both ammonium ion concentration and energy of fragmentation on 4MeI and THI ionization is discussed. The method could be applied for a fast and sensitive determination of 4MeI and THI in di
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytica Chimica Acta
ISSN
0003-2670
e-ISSN
—
Svazek periodika
477
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
10
Strana od-do
49-58