Comparison of Anion-Exchange Membranes for Diffusion Dialysis of Mixtures of Acids and Their Iron Salts
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F24%3A39921747" target="_blank" >RIV/00216275:25310/24:39921747 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.mdpi.com/2077-0375/14/1/6" target="_blank" >https://www.mdpi.com/2077-0375/14/1/6</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/membranes14010006" target="_blank" >10.3390/membranes14010006</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of Anion-Exchange Membranes for Diffusion Dialysis of Mixtures of Acids and Their Iron Salts
Popis výsledku v původním jazyce
This study presents the possibility of using diffusion dialysis for the separation of inorganic acids (hydrochloric, nitric, and hydrofluoric) and their ferric salts whose composition corresponds to that of real spent pickling solutions. At a steady state, the transport properties of three different anion-exchange membranes (Fumasep-FAD, Neosepta-AFN, and Neosepta-AHA) are compared using a continuous counter-current dialyzer. At a constant composition of the solutions (acid concentration 3 mol L-1 and iron concentration 30-40 g L-1), the effects of volumetric liquid flow rates on the transport rate of H+ and Fe3+ ions through the membrane are studied. The dialysis process is characterized by the recovery of acids and the rejection of salts. Furthermore, the values of the dialysis coefficients of acids, iron, and the acid/iron separation factors are calculated and compared. The volumetric flow rates of the inlet streams change in limits from 3 x 10-8 to 6 x 10-8 m3 s-1 (from 3 to 6 L h-1 m-2, relative to the membrane area). A comparison of the tested membranes shows slightly better results for acid recovery, iron rejection, and acid/iron separation factors for the Fumasep-FAD membrane than for the Neosepta-AFN membrane. However, the results obtained show that both of these anion-exchange membranes can be considered good separators for tested mixtures that simulate real spent pickling solutions, and there is a good precondition for using diffusion dialysis for processing these solutions in industrial practice. On the contrary, very low values of acid recovery and the overall dialysis coefficient of acid are found for the Neosepta-AHA membrane in the test range of the volumetric flow rate, and, thus, this membrane is insufficient for the adequate separation of these acids and iron salts.
Název v anglickém jazyce
Comparison of Anion-Exchange Membranes for Diffusion Dialysis of Mixtures of Acids and Their Iron Salts
Popis výsledku anglicky
This study presents the possibility of using diffusion dialysis for the separation of inorganic acids (hydrochloric, nitric, and hydrofluoric) and their ferric salts whose composition corresponds to that of real spent pickling solutions. At a steady state, the transport properties of three different anion-exchange membranes (Fumasep-FAD, Neosepta-AFN, and Neosepta-AHA) are compared using a continuous counter-current dialyzer. At a constant composition of the solutions (acid concentration 3 mol L-1 and iron concentration 30-40 g L-1), the effects of volumetric liquid flow rates on the transport rate of H+ and Fe3+ ions through the membrane are studied. The dialysis process is characterized by the recovery of acids and the rejection of salts. Furthermore, the values of the dialysis coefficients of acids, iron, and the acid/iron separation factors are calculated and compared. The volumetric flow rates of the inlet streams change in limits from 3 x 10-8 to 6 x 10-8 m3 s-1 (from 3 to 6 L h-1 m-2, relative to the membrane area). A comparison of the tested membranes shows slightly better results for acid recovery, iron rejection, and acid/iron separation factors for the Fumasep-FAD membrane than for the Neosepta-AFN membrane. However, the results obtained show that both of these anion-exchange membranes can be considered good separators for tested mixtures that simulate real spent pickling solutions, and there is a good precondition for using diffusion dialysis for processing these solutions in industrial practice. On the contrary, very low values of acid recovery and the overall dialysis coefficient of acid are found for the Neosepta-AHA membrane in the test range of the volumetric flow rate, and, thus, this membrane is insufficient for the adequate separation of these acids and iron salts.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20402 - Chemical process engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Membranes
ISSN
2077-0375
e-ISSN
2077-0375
Svazek periodika
14
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
11
Strana od-do
6
Kód UT WoS článku
001151284400001
EID výsledku v databázi Scopus
2-s2.0-85183330142