Ultrahigh-Performance Supercritical Fluid Chromatography-Mass Spectrometry in the Clinical Lipidomic Analysis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F24%3A39922037" target="_blank" >RIV/00216275:25310/24:39922037 - isvavai.cz</a>
Výsledek na webu
<a href="https://link.springer.com/protocol/10.1007/978-1-0716-4116-3_18" target="_blank" >https://link.springer.com/protocol/10.1007/978-1-0716-4116-3_18</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ultrahigh-Performance Supercritical Fluid Chromatography-Mass Spectrometry in the Clinical Lipidomic Analysis
Popis výsledku v původním jazyce
Ultrahigh-performance supercritical fluid chromatography–mass spectrometry (UHPSFC/MS) method is optimized for the high-throughput quantitation of lipids in human serum and plasma with an emphasis on robustness and accurate quantitation. Bridged ethylene hybrid (BEH) silica column (100 × 3 mm; 1.7 μm) is used for the separation of 17 nonpolar and polar lipid classes in 4.4 min using the positive ion electrospray ionization mode. The lipid class separation approach in UHPSFC/MS results in the coelution of all lipid species within one lipid class in one chromatographic peak, including two exogenous internal standards (IS) per lipid class, which provides the optimal conditions for robust quantitation. The method was validated according to European Medicines Agency and Food and Drug Administration recommendations. UHPSFC/MS combined with LipidQuant software allows a semiautomated process to determine lipid concentrations with a total run time of only 8 min including column equilibration, which enables the analysis of 160 samples per day.
Název v anglickém jazyce
Ultrahigh-Performance Supercritical Fluid Chromatography-Mass Spectrometry in the Clinical Lipidomic Analysis
Popis výsledku anglicky
Ultrahigh-performance supercritical fluid chromatography–mass spectrometry (UHPSFC/MS) method is optimized for the high-throughput quantitation of lipids in human serum and plasma with an emphasis on robustness and accurate quantitation. Bridged ethylene hybrid (BEH) silica column (100 × 3 mm; 1.7 μm) is used for the separation of 17 nonpolar and polar lipid classes in 4.4 min using the positive ion electrospray ionization mode. The lipid class separation approach in UHPSFC/MS results in the coelution of all lipid species within one lipid class in one chromatographic peak, including two exogenous internal standards (IS) per lipid class, which provides the optimal conditions for robust quantitation. The method was validated according to European Medicines Agency and Food and Drug Administration recommendations. UHPSFC/MS combined with LipidQuant software allows a semiautomated process to determine lipid concentrations with a total run time of only 8 min including column equilibration, which enables the analysis of 160 samples per day.
Klasifikace
Druh
C - Kapitola v odborné knize
CEP obor
—
OECD FORD obor
10400 - Chemical sciences
Návaznosti výsledku
Projekt
<a href="/cs/project/NU21-03-00499" target="_blank" >NU21-03-00499: Prospektivní studie na včasnou detekci karcinomu pankreatu a sledování průběhu léčby na základě lipidomického profilování hmotnostní spektrometrií</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
C - Předmět řešení projektu podléhá obchodnímu tajemství (§ 504 Občanského zákoníku), ale název projektu, cíle projektu a u ukončeného nebo zastaveného projektu zhodnocení výsledku řešení projektu (údaje P03, P04, P15, P19, P29, PN8) dodané do CEP, jsou upraveny tak, aby byly zveřejnitelné.
Údaje specifické pro druh výsledku
Název knihy nebo sborníku
Clinical Metabolomics : Methods and Protocols
ISBN
978-1-4939-7592-1
Počet stran výsledku
10
Strana od-do
305-314
Počet stran knihy
575
Název nakladatele
Humana Press
Místo vydání
Totowa
Kód UT WoS kapitoly
—