Sensitive and eco-friendly voltammetric detection of galantamine using a screen-printed sensor with a functional boron-doped diamond electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F25%3A39921673" target="_blank" >RIV/00216275:25310/25:39921673 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0039914024016394?dgcid=coauthor" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0039914024016394?dgcid=coauthor</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2024.127260" target="_blank" >10.1016/j.talanta.2024.127260</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Sensitive and eco-friendly voltammetric detection of galantamine using a screen-printed sensor with a functional boron-doped diamond electrode
Popis výsledku v původním jazyce
The presented study focused on developing and optimizing a modern electroanalytical platform for the direct quantitative determination of galantamine. This work used different voltammetric methods to use a screen-printed sensor with a working boron-doped diamond electrode (SP/BDDE). Beneficial analytical performance for detecting galantamine was achieved in a Britton-Robinson buffer with pH 3.0. The oxidation peaks at 0.92 V and 1.20 V were followed for electrochemical quantification of galantamine. High-resolution mass spectrometry was used for the first time to analyze the products of preparative electrolysis, and a mechanism for the electrochemical oxidation of galantamine was proposed, which describes the demethylation of galantamine and the further oxidation of the hydroxyl group to a ketone group in the galantamine molecule.Coupled with the optimized parameters of differential pulse voltammetry and square-wave voltammetry on the SP/BDDE detected galantamine in two linear ranges (the first range was from 1.22 μM to 10 μM; the second range was from 10 μM to 200 μM), providing the limit of detection and limit of quantification on a micromolar level (0.50 μM and 1.48 μM, respectively). Amperometry and chronoamperometry were employed to develop a rapid detection method for galantamine. In this approach, galantamine can be detected at a level of 1.08 μM (amperometry at the second peak). The selectivity of the optimized amperometric methods was found to be excellent in the presence of ten times higher concentrations of certain interferences. The practical applicability of the SP/BDDE for detecting galantamine was demonstrated through the analysis of pharmaceutical products and human urine samples. The proposed procedure fully complies with the latest requirements of green analytical chemistry.
Název v anglickém jazyce
Sensitive and eco-friendly voltammetric detection of galantamine using a screen-printed sensor with a functional boron-doped diamond electrode
Popis výsledku anglicky
The presented study focused on developing and optimizing a modern electroanalytical platform for the direct quantitative determination of galantamine. This work used different voltammetric methods to use a screen-printed sensor with a working boron-doped diamond electrode (SP/BDDE). Beneficial analytical performance for detecting galantamine was achieved in a Britton-Robinson buffer with pH 3.0. The oxidation peaks at 0.92 V and 1.20 V were followed for electrochemical quantification of galantamine. High-resolution mass spectrometry was used for the first time to analyze the products of preparative electrolysis, and a mechanism for the electrochemical oxidation of galantamine was proposed, which describes the demethylation of galantamine and the further oxidation of the hydroxyl group to a ketone group in the galantamine molecule.Coupled with the optimized parameters of differential pulse voltammetry and square-wave voltammetry on the SP/BDDE detected galantamine in two linear ranges (the first range was from 1.22 μM to 10 μM; the second range was from 10 μM to 200 μM), providing the limit of detection and limit of quantification on a micromolar level (0.50 μM and 1.48 μM, respectively). Amperometry and chronoamperometry were employed to develop a rapid detection method for galantamine. In this approach, galantamine can be detected at a level of 1.08 μM (amperometry at the second peak). The selectivity of the optimized amperometric methods was found to be excellent in the presence of ten times higher concentrations of certain interferences. The practical applicability of the SP/BDDE for detecting galantamine was demonstrated through the analysis of pharmaceutical products and human urine samples. The proposed procedure fully complies with the latest requirements of green analytical chemistry.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Talanta
ISSN
0039-9140
e-ISSN
1873-3573
Svazek periodika
284
Číslo periodika v rámci svazku
March 2025
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
12
Strana od-do
127260
Kód UT WoS článku
001396290900001
EID výsledku v databázi Scopus
2-s2.0-85209948940