Stanovení jodidů s využitím kombinovaného mechanismu akumulace na uhlíkové pastové elektrodě metodou stripping voltametrie
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F98%3A00003868" target="_blank" >RIV/00216275:25310/98:00003868 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Stripping voltammetric determination of iodide with synergistic accumulation at a carbon paste electrode
Popis výsledku v původním jazyce
Carbon paste electrodes (CPEs) of various compositions were studied to elucidate the stripping voltammetric behavior of iodide. At an accumulation potential of +0.7 V (vs. Ag/AgCl), the CPE containing tricresyl phosphate as a pasting liquid was able to preconcetrate iodide effectively via ion-pairing reaction followed by oxidation to iodine and its extraction onto pasting liquid. In a supporting electrolyte containing 0.5 M NaCl and 0.1 M HCl, the reduction signal was proportional to iodide concentration from 5 x 10(-6) to 5 x 10(-7) mol/L with a detection limit of approximately 2.5 x 10(-7) mol/L (accumulation for 5 min). Other halides and pseudohalides did not interfere with the determination, except for a high concentration excess of thiocyanate andbromide (100:1). The method was tested on model solutions and was applied to determine total iodine in samples of table salts and mineral water. The results were compared to those obtained by reference methods.
Název v anglickém jazyce
Stripping voltammetric determination of iodide with synergistic accumulation at a carbon paste electrode
Popis výsledku anglicky
Carbon paste electrodes (CPEs) of various compositions were studied to elucidate the stripping voltammetric behavior of iodide. At an accumulation potential of +0.7 V (vs. Ag/AgCl), the CPE containing tricresyl phosphate as a pasting liquid was able to preconcetrate iodide effectively via ion-pairing reaction followed by oxidation to iodine and its extraction onto pasting liquid. In a supporting electrolyte containing 0.5 M NaCl and 0.1 M HCl, the reduction signal was proportional to iodide concentration from 5 x 10(-6) to 5 x 10(-7) mol/L with a detection limit of approximately 2.5 x 10(-7) mol/L (accumulation for 5 min). Other halides and pseudohalides did not interfere with the determination, except for a high concentration excess of thiocyanate andbromide (100:1). The method was tested on model solutions and was applied to determine total iodine in samples of table salts and mineral water. The results were compared to those obtained by reference methods.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DJ - Znečištění a kontrola vody
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/OE37%2F1" target="_blank" >OE37/1: Levná elektrochemická čidla pro stanovení toxických částic ve znečištěných vodách</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
1998
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
7
Strana od-do
435-441
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—