Tumor bed radiotherapy in women following breast conserving surgery for breast cancer-safety margin with/without image guidance
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25520%2F18%3A39914004" target="_blank" >RIV/00216275:25520/18:39914004 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60162694:G44__/18:43889507 RIV/00216208:11110/18:10375636 RIV/00216208:11120/18:43916511
Výsledek na webu
<a href="http://dx.doi.org/10.3892/ol.2018.8083" target="_blank" >http://dx.doi.org/10.3892/ol.2018.8083</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3892/ol.2018.8083" target="_blank" >10.3892/ol.2018.8083</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Tumor bed radiotherapy in women following breast conserving surgery for breast cancer-safety margin with/without image guidance
Popis výsledku v původním jazyce
Image guided radiation therapy (IGRT) enables the achievement of higher precision in radiation delivery, a reduction in safety margins and a reduced risk of toxicity in healthy tissues. The present study investigated the magnitude of safety margins for the radiation boost setup on skin marks or metal clips implanted into the tumor bed during breast cancer surgery. One hundred eighty-four patients after breast conserving surgery with implanted metal clips into tumor bed were analyzed. The present study investigated the difference in safety margin required for the treatment setup on skin marks and metal clips. The skin marks were created using a positioning laser system in the treatment room. Metal clips implanted in the tumor bed were registered using IGRT with kilovoltage X-rays in orthogonal projection. Treatment setup was performed during free breathing. The safety margin corresponding to the planning target volume (PTV) was calculated from the recorded data. Calculated safety margins for the treatment setup on skin marks were 9.4, 11.1 and 11.1 mm in the anteroposterior, craniocaudal, and laterolateral directions, respectively. Corresponding safety margins with the use of IGRT and metal clips registration were 4.7, 5.1 and 5.9 mm, respectively. The safe PTV margin was 12 mm using setup on skin marks without IGRT, whereas a 6-mm margin was sufficient with the use of metal clip-based IGRT with daily online correction. IGRT has been adopted as the standard treatment method within the Oncology Centre of Multiscan and Pardubice Hospital (Pardubice, Czech Republic).
Název v anglickém jazyce
Tumor bed radiotherapy in women following breast conserving surgery for breast cancer-safety margin with/without image guidance
Popis výsledku anglicky
Image guided radiation therapy (IGRT) enables the achievement of higher precision in radiation delivery, a reduction in safety margins and a reduced risk of toxicity in healthy tissues. The present study investigated the magnitude of safety margins for the radiation boost setup on skin marks or metal clips implanted into the tumor bed during breast cancer surgery. One hundred eighty-four patients after breast conserving surgery with implanted metal clips into tumor bed were analyzed. The present study investigated the difference in safety margin required for the treatment setup on skin marks and metal clips. The skin marks were created using a positioning laser system in the treatment room. Metal clips implanted in the tumor bed were registered using IGRT with kilovoltage X-rays in orthogonal projection. Treatment setup was performed during free breathing. The safety margin corresponding to the planning target volume (PTV) was calculated from the recorded data. Calculated safety margins for the treatment setup on skin marks were 9.4, 11.1 and 11.1 mm in the anteroposterior, craniocaudal, and laterolateral directions, respectively. Corresponding safety margins with the use of IGRT and metal clips registration were 4.7, 5.1 and 5.9 mm, respectively. The safe PTV margin was 12 mm using setup on skin marks without IGRT, whereas a 6-mm margin was sufficient with the use of metal clip-based IGRT with daily online correction. IGRT has been adopted as the standard treatment method within the Oncology Centre of Multiscan and Pardubice Hospital (Pardubice, Czech Republic).
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30204 - Oncology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Oncology letters
ISSN
1792-1074
e-ISSN
—
Svazek periodika
15
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
GR - Řecká republika
Počet stran výsledku
6
Strana od-do
6009-6014
Kód UT WoS článku
000430822500262
EID výsledku v databázi Scopus
2-s2.0-85042668202