Popis výsledku v původním jazyce
Piezoelectric sensors appear to be best suited for picking up acoustic signals thanks to their high sensitivity over a wide frequency range, frequency response stability, design compactness and reliability. Their design differs from sensor to sensor, depending on the type of the measurement to be carried out. Piezoelectric sensors are manufactured on the basis of crystals and polarized dielectrics. They feature, above all, a very good signal-to-noise ratio, a fast response to the load change and a widerange of operating temperatures. Along with the measurements of the noise voltage spectral density, the sensor sensitivity measurements are of high importance not only for the development of acoustic methods but also for the sensor application and, aboveall, checkout. The present paper deals with our test results of piezoelectric sensors from the following viewpoints: frequency range, response uniformity, sensitivity and optimum location of a selected sensor with regard to the amplitude
Název v anglickém jazyce
Optimizing the location of piezoelectric sensors
Popis výsledku anglicky
Piezoelectric sensors appear to be best suited for picking up acoustic signals thanks to their high sensitivity over a wide frequency range, frequency response stability, design compactness and reliability. Their design differs from sensor to sensor, depending on the type of the measurement to be carried out. Piezoelectric sensors are manufactured on the basis of crystals and polarized dielectrics. They feature, above all, a very good signal-to-noise ratio, a fast response to the load change and a widerange of operating temperatures. Along with the measurements of the noise voltage spectral density, the sensor sensitivity measurements are of high importance not only for the development of acoustic methods but also for the sensor application and, aboveall, checkout. The present paper deals with our test results of piezoelectric sensors from the following viewpoints: frequency range, response uniformity, sensitivity and optimum location of a selected sensor with regard to the amplitude
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP103%2F09%2FP247" target="_blank" >GP103/09/P247: Výzkum pasivní metody akustické emise Impact-echo pro nedestruktivní testování ve stavebnictví</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
7th Workshop NDT 2009
ISBN
978-80-7204-671-3
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
Akademické nakladatelství CERM
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
25. 11. 2009
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—