Development of masonry components protected against moisture
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F14%3APU106227" target="_blank" >RIV/00216305:26110/14:PU106227 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMR.860-863.1248" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/AMR.860-863.1248</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMR.860-863.1248" target="_blank" >10.4028/www.scientific.net/AMR.860-863.1248</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development of masonry components protected against moisture
Popis výsledku v původním jazyce
During construction process and life, a number of negative influences can have effect on masonry structures; moisture, which is undesirable in the masonry, can be one of such influences. The lower area of the masonry (plinth walling) is strained the most by the moisture. The paper deals with potential reduction of the effect of moisture in places, where the masonry structure is founded, through hydrophobization of walling units. Such solution of the issue of protection of the building structure against the influence of humidity should not have negative effect on the resulting masonry parameters, particularly not on the potential application of surface treatment materials. The collective influence of the surface treatment materials, consisting usually of plaster, and the actual masonry should be ensured.
Název v anglickém jazyce
Development of masonry components protected against moisture
Popis výsledku anglicky
During construction process and life, a number of negative influences can have effect on masonry structures; moisture, which is undesirable in the masonry, can be one of such influences. The lower area of the masonry (plinth walling) is strained the most by the moisture. The paper deals with potential reduction of the effect of moisture in places, where the masonry structure is founded, through hydrophobization of walling units. Such solution of the issue of protection of the building structure against the influence of humidity should not have negative effect on the resulting masonry parameters, particularly not on the potential application of surface treatment materials. The collective influence of the surface treatment materials, consisting usually of plaster, and the actual masonry should be ensured.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
3rd International Conference on Energy, Environment and Sustainable Development, EESD 2013
ISBN
978-3-03785-972-8
ISSN
1022-6680
e-ISSN
1662-8985
Počet stran výsledku
4
Strana od-do
1248-1251
Název nakladatele
Trans Tech Publications
Místo vydání
Švýcarská konfederace
Místo konání akce
Shanghai
Datum konání akce
12. 11. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000339531800235