To the problems of determination of dynamic elasticity modules of calcium silicate bricks by means of resonance method
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F14%3APU108335" target="_blank" >RIV/00216305:26110/14:PU108335 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
To the problems of determination of dynamic elasticity modules of calcium silicate bricks by means of resonance method
Popis výsledku v původním jazyce
Modulus of elasticity of building materials can be determined in a static way (loading in a press) or by means of non-destructive test methods (ultrasonic pulse method and resonance method); the parameter is most frequently determined for concrete and both methods of determining elasticity modulus are codified in Standards. Elasticity characteristics of calcium silicate bricks were determined by means of resonance test method. Because the shape of calcium silicate bricks (a block with oblong foot) is different from the shape of test specimens for concrete (usually blocks with square foot), expected frequencies for verification of accuracy of measurement by resonance method were determined. Moisture content of calcium silicate bricks (water absorbing capacity is up to 12-14%) has influence on the value of resonance frequency. Difference between dynamic Youngs modulus of elasticity from fundamental longitudinal and transverse resonant frequency is on average 2.8%.
Název v anglickém jazyce
To the problems of determination of dynamic elasticity modules of calcium silicate bricks by means of resonance method
Popis výsledku anglicky
Modulus of elasticity of building materials can be determined in a static way (loading in a press) or by means of non-destructive test methods (ultrasonic pulse method and resonance method); the parameter is most frequently determined for concrete and both methods of determining elasticity modulus are codified in Standards. Elasticity characteristics of calcium silicate bricks were determined by means of resonance test method. Because the shape of calcium silicate bricks (a block with oblong foot) is different from the shape of test specimens for concrete (usually blocks with square foot), expected frequencies for verification of accuracy of measurement by resonance method were determined. Moisture content of calcium silicate bricks (water absorbing capacity is up to 12-14%) has influence on the value of resonance frequency. Difference between dynamic Youngs modulus of elasticity from fundamental longitudinal and transverse resonant frequency is on average 2.8%.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Binders and Materials XI
ISBN
978-3-03835-026-2
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
139-143
Název nakladatele
Trans Tech Publications
Místo vydání
Švýcarsko
Místo konání akce
Brno
Datum konání akce
5. 12. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—