Comparison of dynamic young's modulus of elasticity values measured by ultrasonic pulse and resonance methods
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F15%3APU115645" target="_blank" >RIV/00216305:26110/15:PU115645 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.scientific.net/ARM.1100" target="_blank" >http://www.scientific.net/ARM.1100</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMR.1100.193" target="_blank" >10.4028/www.scientific.net/AMR.1100.193</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of dynamic young's modulus of elasticity values measured by ultrasonic pulse and resonance methods
Popis výsledku v původním jazyce
Dynamic Young´s modulus of elasticity can be determined by ultrasonic pulse method and resonance method. Because of the difference in the way of introducing tension into a test specimen, the values of modulus of elasticity differ. Dynamic Young´s modulus of elasticity measured by ultrasonic pulse method is higher; the difference stated for concrete is 5 to 20%. It was found that the dynamic Young's modulus of elasticity of calcium silicate bricks and prisms measured by ultrasonic pulse method is on average higher by 9.5% than dynamic Young's modulus of elasticity measured by resonance method. If dynamic Young's modulus of elasticity is converted to static modulus of elasticity, this difference has to be taken into account by means of appropriate coefficient.
Název v anglickém jazyce
Comparison of dynamic young's modulus of elasticity values measured by ultrasonic pulse and resonance methods
Popis výsledku anglicky
Dynamic Young´s modulus of elasticity can be determined by ultrasonic pulse method and resonance method. Because of the difference in the way of introducing tension into a test specimen, the values of modulus of elasticity differ. Dynamic Young´s modulus of elasticity measured by ultrasonic pulse method is higher; the difference stated for concrete is 5 to 20%. It was found that the dynamic Young's modulus of elasticity of calcium silicate bricks and prisms measured by ultrasonic pulse method is on average higher by 9.5% than dynamic Young's modulus of elasticity measured by resonance method. If dynamic Young's modulus of elasticity is converted to static modulus of elasticity, this difference has to be taken into account by means of appropriate coefficient.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
12th Conference Silicate Binders 2014
ISBN
978-3-03835-452-9
ISSN
1022-6680
e-ISSN
1662-8985
Počet stran výsledku
4
Strana od-do
193-196
Název nakladatele
Trans Tech Publications
Místo vydání
Švýcarsko
Místo konání akce
Brno
Datum konání akce
4. 12. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce