Appropriateness of Test Cases Included in the CIE 171/2006 Test Report
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F14%3APU112867" target="_blank" >RIV/00216305:26110/14:PU112867 - isvavai.cz</a>
Výsledek na webu
<a href="https://perswww.kuleuven.be/~u0046505/ATF2014/proceedings_files/E-book_ATF_Conference_2014.pdf" target="_blank" >https://perswww.kuleuven.be/~u0046505/ATF2014/proceedings_files/E-book_ATF_Conference_2014.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Appropriateness of Test Cases Included in the CIE 171/2006 Test Report
Popis výsledku v původním jazyce
Methodologies used to obtain the values of certain quantities in the branches of building physics are quite often simplified. Daylighting design of buildings as much as the field of building acoustics and many other is not an exception to this statement.The numerical and graphical methods including the ones used in computer design tools for the determination of daylight factor levels inside buildings are often based on sky models and surface description, which does not correspond to reality, at least not at a full scale. Hence all of the calculations do have an errata, may it be small or big. To prevent the appearance of such mistakes CIE as the one and only internationally recognized organization did issue out a publication in the year of 2006, namely the CIE 171/2006 test report which can be used to assess the qualities of a lighting design tools whilst determining illuminance or daylight factor levels. However most of the test cases do test the capabilities of daylighting design to
Název v anglickém jazyce
Appropriateness of Test Cases Included in the CIE 171/2006 Test Report
Popis výsledku anglicky
Methodologies used to obtain the values of certain quantities in the branches of building physics are quite often simplified. Daylighting design of buildings as much as the field of building acoustics and many other is not an exception to this statement.The numerical and graphical methods including the ones used in computer design tools for the determination of daylight factor levels inside buildings are often based on sky models and surface description, which does not correspond to reality, at least not at a full scale. Hence all of the calculations do have an errata, may it be small or big. To prevent the appearance of such mistakes CIE as the one and only internationally recognized organization did issue out a publication in the year of 2006, namely the CIE 171/2006 test report which can be used to assess the qualities of a lighting design tools whilst determining illuminance or daylight factor levels. However most of the test cases do test the capabilities of daylighting design to
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
ATF 2014 e-book of reviewed papers
ISBN
978-3-200-03644-4
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
228-231
Název nakladatele
TGM - Federal Institute of Technology
Místo vydání
Vienna, Austria
Místo konání akce
Vienna
Datum konání akce
6. 5. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—