Evaluation of the Thermal Resistance of Structure with Reflective Insulation: Measurement under Non-Stationary Boundary Conditions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F14%3APU114329" target="_blank" >RIV/00216305:26110/14:PU114329 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMR.1041.150" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/AMR.1041.150</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMR.1041.150" target="_blank" >10.4028/www.scientific.net/AMR.1041.150</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of the Thermal Resistance of Structure with Reflective Insulation: Measurement under Non-Stationary Boundary Conditions
Popis výsledku v původním jazyce
Some manufacturers of reflective insulation products claim that their relatively thin products have the same thermal insulation properties as common insulation with much times higher thickness. This paper deals with experimental measurements of the thermal insulation properties of real structures with reflective insulation.Several experimental sequences were conducted to determine thethermal resistance of the structure. The evaluation was conducted according to the procedures specified in the international standard (ISO 9869 - 1994). Effect of products (based on the reflection of thermal radiation) on the thermal insulation properties of the structure will be determined by evaluation. This effect will be compared with the effects of commoninsulation(with the intention of reduceof theheat transfer by the conduction).
Název v anglickém jazyce
Evaluation of the Thermal Resistance of Structure with Reflective Insulation: Measurement under Non-Stationary Boundary Conditions
Popis výsledku anglicky
Some manufacturers of reflective insulation products claim that their relatively thin products have the same thermal insulation properties as common insulation with much times higher thickness. This paper deals with experimental measurements of the thermal insulation properties of real structures with reflective insulation.Several experimental sequences were conducted to determine thethermal resistance of the structure. The evaluation was conducted according to the procedures specified in the international standard (ISO 9869 - 1994). Effect of products (based on the reflection of thermal radiation) on the thermal insulation properties of the structure will be determined by evaluation. This effect will be compared with the effects of commoninsulation(with the intention of reduceof theheat transfer by the conduction).
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP104%2F12%2F1838" target="_blank" >GAP104/12/1838: Využití akumulace latetního tepla materiály s fázovou změnou pro snížení spotřeby primární energie v budovách</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Advanced Materials Research (online)
ISSN
1022-6680
e-ISSN
1662-8985
Svazek periodika
1041
Číslo periodika v rámci svazku
1041
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
4
Strana od-do
150-153
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-84921491193