Test of Adhesion and Shear Strength of Polyurethane Adhesives to Cement-bonded Particleboard
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F15%3APU111677" target="_blank" >RIV/00216305:26110/15:PU111677 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.scientific.net/AMR.1100.185" target="_blank" >http://www.scientific.net/AMR.1100.185</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMR.1100.185" target="_blank" >10.4028/www.scientific.net/AMR.1100.185</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Test of Adhesion and Shear Strength of Polyurethane Adhesives to Cement-bonded Particleboard
Popis výsledku v původním jazyce
This research case was carried out to examine the possibility of usage of cement-bonded composite particleboards as a sheathing of a vented façade system with bonded joints. The potential of bonded joints in combination with composite cladding material was studied and described in more detail as well as verified through experimental measurements. For the purpose of tests spruce timber profiles were chosen for the load bearing substructure. Three types of industrial adhesives intended for structural bonding were selected. The article is focused on the preparation as well as on the subsequent experimental verification of the substructure bonding retention to the cladding and the determination of shear strength under tensile stress at a temperature of (20.0+/-3) oC and a relative humidity of (55.0+/-10) %. The test results proved the fact that bonded joints are more than suitable equivalent to the mechanical joints. Furthermore, the series of tests verified the suitability of use of the chosen adhesives in combination with cement-bonded particleboard.
Název v anglickém jazyce
Test of Adhesion and Shear Strength of Polyurethane Adhesives to Cement-bonded Particleboard
Popis výsledku anglicky
This research case was carried out to examine the possibility of usage of cement-bonded composite particleboards as a sheathing of a vented façade system with bonded joints. The potential of bonded joints in combination with composite cladding material was studied and described in more detail as well as verified through experimental measurements. For the purpose of tests spruce timber profiles were chosen for the load bearing substructure. Three types of industrial adhesives intended for structural bonding were selected. The article is focused on the preparation as well as on the subsequent experimental verification of the substructure bonding retention to the cladding and the determination of shear strength under tensile stress at a temperature of (20.0+/-3) oC and a relative humidity of (55.0+/-10) %. The test results proved the fact that bonded joints are more than suitable equivalent to the mechanical joints. Furthermore, the series of tests verified the suitability of use of the chosen adhesives in combination with cement-bonded particleboard.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/FR-TI4%2F332" target="_blank" >FR-TI4/332: Nové technologie lepených obvodových plášťů budov s kotvícími prvky se zvýšenou odolností vůči korozi</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Advanced Materials Research
ISSN
1022-6680
e-ISSN
1662-8985
Svazek periodika
1100
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
4
Strana od-do
185-188
Kód UT WoS článku
—