THE APPLICABILITY OF EXISTING METHODS FOR TESTING THE BASE LAYERS OF ETICS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F15%3APU117873" target="_blank" >RIV/00216305:26110/15:PU117873 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
THE APPLICABILITY OF EXISTING METHODS FOR TESTING THE BASE LAYERS OF ETICS
Popis výsledku v původním jazyce
The contact thermal insulation system is a major trend in building construction in the Czech Republic. In this way both for new buildings and for renovations to improve thermal and technical parameters of buildings. Effort of an extension of the construction season, however, causes frequent visits of the application of this system in unsuitable weather conditions. One of the important layers in the systems ETICS (which is the contact thermal insulation of the building) is the basic layer with glass-fibre reinforcing mesh. Such a cover layer of thermal insulation and at the same time a basis for the final outer layer - plaster. Climatic conditions during application are given by the manufacturer. Normal temperature is indicated by + 5°C to +30°C. The lower boundary is not often observed. That's why I have my research and thesis focused on testing the parameters of the base layer made outside the ideal conditions. I thus produced samples underwent laboratory tests and watching the result
Název v anglickém jazyce
THE APPLICABILITY OF EXISTING METHODS FOR TESTING THE BASE LAYERS OF ETICS
Popis výsledku anglicky
The contact thermal insulation system is a major trend in building construction in the Czech Republic. In this way both for new buildings and for renovations to improve thermal and technical parameters of buildings. Effort of an extension of the construction season, however, causes frequent visits of the application of this system in unsuitable weather conditions. One of the important layers in the systems ETICS (which is the contact thermal insulation of the building) is the basic layer with glass-fibre reinforcing mesh. Such a cover layer of thermal insulation and at the same time a basis for the final outer layer - plaster. Climatic conditions during application are given by the manufacturer. Normal temperature is indicated by + 5°C to +30°C. The lower boundary is not often observed. That's why I have my research and thesis focused on testing the parameters of the base layer made outside the ideal conditions. I thus produced samples underwent laboratory tests and watching the result
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EnviBUILD ? Budovy a prostredie 2015
ISBN
978-80-227-4469-0
ISSN
—
e-ISSN
—
Počet stran výsledku
129
Strana od-do
80-80
Název nakladatele
STU ? Nakladateľstvo STU, Bratislava
Místo vydání
Bratislava
Místo konání akce
Bratislava
Datum konání akce
15. 10. 2015
Typ akce podle státní příslušnosti
EUR - Evropská akce