Study of the Moisture Behavior of Newly Developed Plasters Applied on Brick Pillars
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F16%3APU119840" target="_blank" >RIV/00216305:26110/16:PU119840 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S187770581631757X" target="_blank" >http://www.sciencedirect.com/science/article/pii/S187770581631757X</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.proeng.2016.07.369" target="_blank" >10.1016/j.proeng.2016.07.369</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Study of the Moisture Behavior of Newly Developed Plasters Applied on Brick Pillars
Popis výsledku v původním jazyce
As part of research works devoted to the development of silicate thermal insulation materials, two mixtures of plasters based on lightweight aggregate and on traditional and alternative binders were designed. The laboratory-prepared plasters were applied to masonry columns, in which probes were incorporated for monitoring changes in moisture. After the plasters had hardened, the structure fragments were flooded with water of a constant level for the whole duration of the long-term measurement. For monitoring the moisture profile, 2 methods of measurement were used. It was electrical impedance spectrometry and determination of moisture content using a capacitive hygrometer.
Název v anglickém jazyce
Study of the Moisture Behavior of Newly Developed Plasters Applied on Brick Pillars
Popis výsledku anglicky
As part of research works devoted to the development of silicate thermal insulation materials, two mixtures of plasters based on lightweight aggregate and on traditional and alternative binders were designed. The laboratory-prepared plasters were applied to masonry columns, in which probes were incorporated for monitoring changes in moisture. After the plasters had hardened, the structure fragments were flooded with water of a constant level for the whole duration of the long-term measurement. For monitoring the moisture profile, 2 methods of measurement were used. It was electrical impedance spectrometry and determination of moisture content using a capacitive hygrometer.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
ICEBMP 2016 Ekologie a nové stavebí hmoty a výrobky
ISBN
978-80-87397-23-7
ISSN
1877-7058
e-ISSN
—
Počet stran výsledku
8
Strana od-do
58-65
Název nakladatele
Elsevier
Místo vydání
Nizozemsko
Místo konání akce
Černá Hora
Datum konání akce
31. 5. 2016
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000387482800008