Observation of moisture behaviour of thermal insulation materials based on silicates
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F16%3APU120734" target="_blank" >RIV/00216305:26110/16:PU120734 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Observation of moisture behaviour of thermal insulation materials based on silicates
Popis výsledku v původním jazyce
Moisture plays very an important role in insulation materials from the view of possible degradation of thermal insulation properties. During the development of lightweight, thermal insulation plasters based on silicate were used special hydrophobic agents based on oleates and stearates. The aim of research works was to study the moisture transport in these developed materials that have been burdened with permanent moisture effect. Two non-destructive methods were used for monitoring of moisture transport; method of electrical impedance spectroscopy (EIS) and then was made determination of mass moisture using the apparatus – capacity moisture meter. Evaluation of measurement results demonstrated a substantially lower moisture sensitivity in comparison with commonly used thermal insulation plasters in Czech Republic.
Název v anglickém jazyce
Observation of moisture behaviour of thermal insulation materials based on silicates
Popis výsledku anglicky
Moisture plays very an important role in insulation materials from the view of possible degradation of thermal insulation properties. During the development of lightweight, thermal insulation plasters based on silicate were used special hydrophobic agents based on oleates and stearates. The aim of research works was to study the moisture transport in these developed materials that have been burdened with permanent moisture effect. Two non-destructive methods were used for monitoring of moisture transport; method of electrical impedance spectroscopy (EIS) and then was made determination of mass moisture using the apparatus – capacity moisture meter. Evaluation of measurement results demonstrated a substantially lower moisture sensitivity in comparison with commonly used thermal insulation plasters in Czech Republic.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů