Electrical Impedance Used for Measurement of Moisture Distribution in Thermal Insulation Plasters
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F19%3APU131986" target="_blank" >RIV/00216305:26110/19:PU131986 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.3311/PPci.10901" target="_blank" >https://doi.org/10.3311/PPci.10901</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3311/PPci.10901" target="_blank" >10.3311/PPci.10901</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrical Impedance Used for Measurement of Moisture Distribution in Thermal Insulation Plasters
Popis výsledku v původním jazyce
High moisture in building materials has a negative influence on their physical and thermal insulating properties. When building materials incorporated in a structure exceed the maximum permissible moisture, the material could change its properties to such an extent that its next usage is unfeasible. In case of thermal insulating materials, it causes serious degradation of thermal insulating properties. During the development of advanced thermal insulation plasters, long-term laboratory experiments were performed using masonry construction fragments, which focused on the study of their moisture proportions. For this purpose a new non-destructive method of electrical impedance was used, which enables measurements on defined levels in a matrix of test samples. Results obtained by measurements made on the surface of the samples were compared with the results obtained by a capacitive hygrometer. It was concluded that these methods provided similar results. The least moisture sensitive was the mixture, which was applied on masonry pillar E. In comparison with used thermal insulation plasters commonly used today this plaster shows considerably lower value of mass moisture under laboratory conditions, 1.38%. This pillar also exhibited the most uniform course of conductance measured along its height
Název v anglickém jazyce
Electrical Impedance Used for Measurement of Moisture Distribution in Thermal Insulation Plasters
Popis výsledku anglicky
High moisture in building materials has a negative influence on their physical and thermal insulating properties. When building materials incorporated in a structure exceed the maximum permissible moisture, the material could change its properties to such an extent that its next usage is unfeasible. In case of thermal insulating materials, it causes serious degradation of thermal insulating properties. During the development of advanced thermal insulation plasters, long-term laboratory experiments were performed using masonry construction fragments, which focused on the study of their moisture proportions. For this purpose a new non-destructive method of electrical impedance was used, which enables measurements on defined levels in a matrix of test samples. Results obtained by measurements made on the surface of the samples were compared with the results obtained by a capacitive hygrometer. It was concluded that these methods provided similar results. The least moisture sensitive was the mixture, which was applied on masonry pillar E. In comparison with used thermal insulation plasters commonly used today this plaster shows considerably lower value of mass moisture under laboratory conditions, 1.38%. This pillar also exhibited the most uniform course of conductance measured along its height
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Periodica Polytechnica - Civil Engineering
ISSN
0553-6626
e-ISSN
—
Svazek periodika
63
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
HU - Maďarsko
Počet stran výsledku
10
Strana od-do
489-498
Kód UT WoS článku
000469935200015
EID výsledku v databázi Scopus
2-s2.0-85070611704