Hydraulic design of storm water infiltration facility including uncertainties
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F16%3APU120870" target="_blank" >RIV/00216305:26110/16:PU120870 - isvavai.cz</a>
Výsledek na webu
<a href="http://acta.mendelu.cz/artkey/acu-201605-0007_hydraulic-design-of-stormwater-infiltration-facility-including-uncertainties.php" target="_blank" >http://acta.mendelu.cz/artkey/acu-201605-0007_hydraulic-design-of-stormwater-infiltration-facility-including-uncertainties.php</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.11118/actaun201664051483" target="_blank" >10.11118/actaun201664051483</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Hydraulic design of storm water infiltration facility including uncertainties
Popis výsledku v původním jazyce
For a design of the volume of the rainfall infiltration facility, the coefficient of infiltration is determined by an infiltration test. The use of the coefficient of infiltration brings certain uncertainties into the solution, arising from different conditions in carrying out the infiltration test and in operating a real infiltration facility. In this study an analysis is carried out of factors that influence the process of infiltration and related uncertainties influencing the determination of the storage volume of the infiltration facility. The effect of the individual factors on the design of the infiltration facility was analyzed using numerical simulations by the software HYDRUS-2D and expressed using partial reliability factors. For their determination the nomographs were set up by extensive numerical computations.
Název v anglickém jazyce
Hydraulic design of storm water infiltration facility including uncertainties
Popis výsledku anglicky
For a design of the volume of the rainfall infiltration facility, the coefficient of infiltration is determined by an infiltration test. The use of the coefficient of infiltration brings certain uncertainties into the solution, arising from different conditions in carrying out the infiltration test and in operating a real infiltration facility. In this study an analysis is carried out of factors that influence the process of infiltration and related uncertainties influencing the determination of the storage volume of the infiltration facility. The effect of the individual factors on the design of the infiltration facility was analyzed using numerical simulations by the software HYDRUS-2D and expressed using partial reliability factors. For their determination the nomographs were set up by extensive numerical computations.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Universitatis Agriculturae et Silviculturae Mendelianae Brunensis
ISSN
1211-8516
e-ISSN
2464-8310
Svazek periodika
64
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
12
Strana od-do
1483-1494
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-84994525800