Stormwater Infiltration Facilities-Philosophy, Design.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F17%3APU123678" target="_blank" >RIV/00216305:26110/17:PU123678 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.psipw.org/index.php?option=com_content&view=article&id=394" target="_blank" >http://www.psipw.org/index.php?option=com_content&view=article&id=394</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Stormwater Infiltration Facilities-Philosophy, Design.
Popis výsledku v původním jazyce
Present approach to the integrated stormwater control consists in the accumulation and infiltration of rainwater at the place of its origin. For a design of the volume of the rainfall infiltration facility, the coefficient of infiltration is determined by an infiltration test. The design is subject to numerous uncertainties, arising from different conditions in carrying out the infiltration test and in operating a real infiltration facility. In this study the review of the most used facilities for infiltration is presented. An analysis of factors influencing the process of infiltration is carried out,relevant uncertainties influencing the design of the storage volume of the infiltration facility are discussed. The values of correction factors related to individual uncertainties arerecommended.
Název v anglickém jazyce
Stormwater Infiltration Facilities-Philosophy, Design.
Popis výsledku anglicky
Present approach to the integrated stormwater control consists in the accumulation and infiltration of rainwater at the place of its origin. For a design of the volume of the rainfall infiltration facility, the coefficient of infiltration is determined by an infiltration test. The design is subject to numerous uncertainties, arising from different conditions in carrying out the infiltration test and in operating a real infiltration facility. In this study the review of the most used facilities for infiltration is presented. An analysis of factors influencing the process of infiltration is carried out,relevant uncertainties influencing the design of the storage volume of the infiltration facility are discussed. The values of correction factors related to individual uncertainties arerecommended.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/TA04020670" target="_blank" >TA04020670: Využití spolehlivostních metod při technickobezpečnostním dohledu nad vodními díly s ohledem na jejich bezpečnost v období globálních klimatických změn.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Water Resources and Arid Environments
ISSN
2079-7079
e-ISSN
—
Svazek periodika
Neuveden
Číslo periodika v rámci svazku
6/2017
Stát vydavatele periodika
SA - Království Saúdská Arábie
Počet stran výsledku
8
Strana od-do
33-40
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—