Fracture parameters of concrete after exposure to high temperatures: pilot tests
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F17%3APU123716" target="_blank" >RIV/00216305:26110/17:PU123716 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.matec-conferences.org/articles/matecconf/abs/2017/21/matecconf_dyn2017_00039/matecconf_dyn2017_00039.html" target="_blank" >https://www.matec-conferences.org/articles/matecconf/abs/2017/21/matecconf_dyn2017_00039/matecconf_dyn2017_00039.html</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/matecconf/201710700039" target="_blank" >10.1051/matecconf/201710700039</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Fracture parameters of concrete after exposure to high temperatures: pilot tests
Popis výsledku v původním jazyce
Experimental concrete panels were after an appropriate aging time loaded by high temperatures (550, 600, 800 and 1000 °C) in a furnace intended for fire tests of building materials. These panels were heated according to the standard temperature-time curve according to EN 1991-1-2. One of panels was a reference without temperature load. Test specimens were obtained as cores drilled out from panels after performing fire tests. The cylindrical specimens were provided with a central chevron type notch and subsequently tested in three-point bending fracture test. The load versus displacement (deflection in the middle of span) diagrams were recorded during testing and basic fracture parameters were subsequently evaluated.
Název v anglickém jazyce
Fracture parameters of concrete after exposure to high temperatures: pilot tests
Popis výsledku anglicky
Experimental concrete panels were after an appropriate aging time loaded by high temperatures (550, 600, 800 and 1000 °C) in a furnace intended for fire tests of building materials. These panels were heated according to the standard temperature-time curve according to EN 1991-1-2. One of panels was a reference without temperature load. Test specimens were obtained as cores drilled out from panels after performing fire tests. The cylindrical specimens were provided with a central chevron type notch and subsequently tested in three-point bending fracture test. The load versus displacement (deflection in the middle of span) diagrams were recorded during testing and basic fracture parameters were subsequently evaluated.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA16-18702S" target="_blank" >GA16-18702S: Problematika porušování v blízkosti rozhraní plniva a matrice kompozitů na silikátové bázi (AMIRI)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
MATEC Web of Conferences: Dynamics of Civil Engineering and Transport Structures and Wind Engineering – DYN-WIND’2017
ISBN
—
ISSN
2261-236X
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
EDP Sciences
Místo vydání
France
Místo konání akce
Trstená
Datum konání akce
21. 5. 2017
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000407745800039