Mechanical Fracture Parameters of Concrete Specimens from One-Side-Heated Panels
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F17%3APU125019" target="_blank" >RIV/00216305:26110/17:PU125019 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Mechanical Fracture Parameters of Concrete Specimens from One-Side-Heated Panels
Popis výsledku v původním jazyce
This study deals with the characterization of fire damaged concrete panels. The attention is paid to determination of selected mechanical fracture parameters via evaluation of fracture tests of specimens from the concrete panels after their exposure to elevated temperatures. Experimental panels were heated according to the dynamic temperature-time curve ISO 834 (given by EN 1991-1-2.2010) with a subsequent maintained maximum nominal temperature 550, 600, 800 and 1000 °C for 60 minutes. Test specimens were obtained by cutting out from concrete panels after performing fire tests and provided with initial central edge notch. These specimens were tested in three-point bending test and loaded under displacement control. The load versus displacement and load versus crack mouth opening displacement diagrams were obtained and selected fracture parameters were subsequently evaluated: modulus of elasticity, effective crack elongation, effective fracture toughness and specific fracture energy.
Název v anglickém jazyce
Mechanical Fracture Parameters of Concrete Specimens from One-Side-Heated Panels
Popis výsledku anglicky
This study deals with the characterization of fire damaged concrete panels. The attention is paid to determination of selected mechanical fracture parameters via evaluation of fracture tests of specimens from the concrete panels after their exposure to elevated temperatures. Experimental panels were heated according to the dynamic temperature-time curve ISO 834 (given by EN 1991-1-2.2010) with a subsequent maintained maximum nominal temperature 550, 600, 800 and 1000 °C for 60 minutes. Test specimens were obtained by cutting out from concrete panels after performing fire tests and provided with initial central edge notch. These specimens were tested in three-point bending test and loaded under displacement control. The load versus displacement and load versus crack mouth opening displacement diagrams were obtained and selected fracture parameters were subsequently evaluated: modulus of elasticity, effective crack elongation, effective fracture toughness and specific fracture energy.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA16-18702S" target="_blank" >GA16-18702S: Problematika porušování v blízkosti rozhraní plniva a matrice kompozitů na silikátové bázi (AMIRI)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
SP Report: Proceedings from the 5 th International Workshop on Concrete Spalling
ISBN
—
ISSN
0284-5172
e-ISSN
—
Počet stran výsledku
7
Strana od-do
105-111
Název nakladatele
RISE Research Institute of Sweden AB
Místo vydání
Boras
Místo konání akce
Boras
Datum konání akce
12. 10. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—