The Issue of the Daylighting intensity by Light Guides
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F18%3APU128857" target="_blank" >RIV/00216305:26110/18:PU128857 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Issue of the Daylighting intensity by Light Guides
Popis výsledku v původním jazyce
The issue of the efficiency of use and determination of the operational efficiency of the designed light sources is relevant during the process of lighting design. The contribution deals with the illumination of the interior by the tubular light guides during design and operation itself. The measurement of the luminance, the illumination of the exterior and the interior was carried out on experimental wooden building in Brno belonging to VUT FAST (Czech Republic). In one case, the brightness of the sky was also measured. The assessed tubular light guides Sunizer with the length of tube 2 m and with the diameter of 320 mm passes through the roof structure and through the ceiling structure into the interior corridor of the wooden building. Prior to the start of the measurement, the measuring sensors were placed in the center of the diffusers of the two measured tubular light guides at the floor level. Another one sensor was placed at the midpoint between the diffusers at the floor level. Subsequently, a
Název v anglickém jazyce
The Issue of the Daylighting intensity by Light Guides
Popis výsledku anglicky
The issue of the efficiency of use and determination of the operational efficiency of the designed light sources is relevant during the process of lighting design. The contribution deals with the illumination of the interior by the tubular light guides during design and operation itself. The measurement of the luminance, the illumination of the exterior and the interior was carried out on experimental wooden building in Brno belonging to VUT FAST (Czech Republic). In one case, the brightness of the sky was also measured. The assessed tubular light guides Sunizer with the length of tube 2 m and with the diameter of 320 mm passes through the roof structure and through the ceiling structure into the interior corridor of the wooden building. Prior to the start of the measurement, the measuring sensors were placed in the center of the diffusers of the two measured tubular light guides at the floor level. Another one sensor was placed at the midpoint between the diffusers at the floor level. Subsequently, a
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20103 - Architecture engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1408" target="_blank" >LO1408: AdMaS UP - Pokročilé stavební materiály, konstrukce a technologie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů