The Issue of the Daylighting Intensity by Light Guides
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F19%3APU131033" target="_blank" >RIV/00216305:26110/19:PU131033 - isvavai.cz</a>
Výsledek na webu
<a href="https://iopscience-iop-org.ezproxy.lib.vutbr.cz/article/10.1088/1757-899X/471/6/062025" target="_blank" >https://iopscience-iop-org.ezproxy.lib.vutbr.cz/article/10.1088/1757-899X/471/6/062025</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/471/6/062025" target="_blank" >10.1088/1757-899X/471/6/062025</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Issue of the Daylighting Intensity by Light Guides
Popis výsledku v původním jazyce
The issue of the efficiency of use and determination of the operational efficiency of the designed light sources is relevant during the process of lighting design. The contribution deals with the illumination of the interior by the tubular light guides during design and operation itself. The measurement of the luminance, the illumination of the exterior and the interior was carried out on experimental wooden building in Brno belonging to VUT FAST (Czech Republic). In one case, the brightness of the sky was also measured. The assessed tubular light guides Sunizer with the length of tube 2 m and with the diameter of 320 mm passes through the roof structure and through the ceiling structure into the interior corridor of the wooden building. Prior to the start of the measurement, the measuring sensors were placed in the center of the diffusers of the two measured tubular light guides at the floor level. Another one sensor was placed at the midpoint between the diffusers at the floor level. Subsequently, another sensor was placed on the roof of the building in the exterior. The sensor is placed next to the dome of the light guide so that it is not overshadowed. The sensors were connected to the datalogger and the 5-minute measurement was performed at all four locations simultaneously at time intervals after one minute. The values of the sky brightness always in four directions were determined were determined before the measurement, in the middle of the measurement and at the end of the measurement. The sky type was determined visually for some of the measurements. Finally, the measured data from the luxmeter was stored and the ratios of illumination of the interior and exterior were calculated. Subsequently, the measured data are compared with the simulations obtained from the software Holigilm and Velux Daylight Visualizer. The benchmark is the ratio between indoor and outdoor illumination, the so-called daylight factor. Finally, there is an evaluation, a graph showing
Název v anglickém jazyce
The Issue of the Daylighting Intensity by Light Guides
Popis výsledku anglicky
The issue of the efficiency of use and determination of the operational efficiency of the designed light sources is relevant during the process of lighting design. The contribution deals with the illumination of the interior by the tubular light guides during design and operation itself. The measurement of the luminance, the illumination of the exterior and the interior was carried out on experimental wooden building in Brno belonging to VUT FAST (Czech Republic). In one case, the brightness of the sky was also measured. The assessed tubular light guides Sunizer with the length of tube 2 m and with the diameter of 320 mm passes through the roof structure and through the ceiling structure into the interior corridor of the wooden building. Prior to the start of the measurement, the measuring sensors were placed in the center of the diffusers of the two measured tubular light guides at the floor level. Another one sensor was placed at the midpoint between the diffusers at the floor level. Subsequently, another sensor was placed on the roof of the building in the exterior. The sensor is placed next to the dome of the light guide so that it is not overshadowed. The sensors were connected to the datalogger and the 5-minute measurement was performed at all four locations simultaneously at time intervals after one minute. The values of the sky brightness always in four directions were determined were determined before the measurement, in the middle of the measurement and at the end of the measurement. The sky type was determined visually for some of the measurements. Finally, the measured data from the luxmeter was stored and the ratios of illumination of the interior and exterior were calculated. Subsequently, the measured data are compared with the simulations obtained from the software Holigilm and Velux Daylight Visualizer. The benchmark is the ratio between indoor and outdoor illumination, the so-called daylight factor. Finally, there is an evaluation, a graph showing
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
60402 - Architectural design
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1408" target="_blank" >LO1408: AdMaS UP - Pokročilé stavební materiály, konstrukce a technologie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IOP Conference Series: Materials Science and Engineering
ISBN
—
ISSN
1757-8981
e-ISSN
—
Počet stran výsledku
11
Strana od-do
1-11
Název nakladatele
IOP PUBLISHING LTD
Místo vydání
BRISTOL
Místo konání akce
Praha
Datum konání akce
18. 6. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000465811802076