CHARACTERIZATION OF CEMENT-BASED COMPOSITE EXPOSED TO HIGH TEMPERATURES VIA ULTRASONIC PULSE METHOD
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F18%3APU131218" target="_blank" >RIV/00216305:26110/18:PU131218 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.14311/APP.2018.15.0099" target="_blank" >http://dx.doi.org/10.14311/APP.2018.15.0099</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/APP.2018.15.0099" target="_blank" >10.14311/APP.2018.15.0099</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
CHARACTERIZATION OF CEMENT-BASED COMPOSITE EXPOSED TO HIGH TEMPERATURES VIA ULTRASONIC PULSE METHOD
Popis výsledku v původním jazyce
In this paper, the attention is paid to the investigation of the influence of high temperature acting on specimens made from specially designed cement-based composite. The experimental programme was carried out on six sets of beam specimens with the dimensions of 20 x 40 x 200 mm. The specimens were loaded to a pre-set temperature of 100, 200, 400, 600, 800 and 1000 C and then the temperature was kept for 60 minutes. When the temperature loading had been done, the specimens were left to cool down to the ambient temperature. After that, the ultrasonic pulse method was used to determine the degree of damage of temperature loaded specimens. The measured data obtained by this non-destructive method are in high correlation with values of informative compressive strength of the composite obtained after the temperature loading of specimens.
Název v anglickém jazyce
CHARACTERIZATION OF CEMENT-BASED COMPOSITE EXPOSED TO HIGH TEMPERATURES VIA ULTRASONIC PULSE METHOD
Popis výsledku anglicky
In this paper, the attention is paid to the investigation of the influence of high temperature acting on specimens made from specially designed cement-based composite. The experimental programme was carried out on six sets of beam specimens with the dimensions of 20 x 40 x 200 mm. The specimens were loaded to a pre-set temperature of 100, 200, 400, 600, 800 and 1000 C and then the temperature was kept for 60 minutes. When the temperature loading had been done, the specimens were left to cool down to the ambient temperature. After that, the ultrasonic pulse method was used to determine the degree of damage of temperature loaded specimens. The measured data obtained by this non-destructive method are in high correlation with values of informative compressive strength of the composite obtained after the temperature loading of specimens.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA16-18702S" target="_blank" >GA16-18702S: Problematika porušování v blízkosti rozhraní plniva a matrice kompozitů na silikátové bázi (AMIRI)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
9th annual Conference NANO & MACRO MECHANICS 2018
ISBN
978-80-01-06457-3
ISSN
2336-5382
e-ISSN
—
Počet stran výsledku
5
Strana od-do
99-103
Název nakladatele
Czech Technical University in Prague
Místo vydání
Praha
Místo konání akce
Prague
Datum konání akce
20. 9. 2018
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
000461834500018