Daylight Illuminance Data Measurement and Processing for a Physical Scale Model
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F24%3APU150521" target="_blank" >RIV/00216305:26110/24:PU150521 - isvavai.cz</a>
Výsledek na webu
<a href="https://ascelibrary.org/doi/10.1061/JAEIED.AEENG-1518" target="_blank" >https://ascelibrary.org/doi/10.1061/JAEIED.AEENG-1518</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1061/JAEIED.AEENG-1518" target="_blank" >10.1061/JAEIED.AEENG-1518</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Daylight Illuminance Data Measurement and Processing for a Physical Scale Model
Popis výsledku v původním jazyce
Continual two-year measurements of daylight illuminance were performed in order to evaluate the daylighting of a model room. The key research idea was to study room orientation and its effect on daylight availability by using real measurements from a physical scale model. Firstly, differences between the illuminance in the north- and south-oriented rooms were compared. Secondly, a characteristic annual profile of the external horizontal illuminance data was determined. Finally, the median external diffuse illuminance data from measurements were compared with values based on the values recommended in the standard. The goal of the research was focused on the evaluation of a regional daylight climate model applicable for daylight evaluations. The results of the daylight illuminance measurements showed the importance of climatic daylight data for indoor daylighting in building design performance.
Název v anglickém jazyce
Daylight Illuminance Data Measurement and Processing for a Physical Scale Model
Popis výsledku anglicky
Continual two-year measurements of daylight illuminance were performed in order to evaluate the daylighting of a model room. The key research idea was to study room orientation and its effect on daylight availability by using real measurements from a physical scale model. Firstly, differences between the illuminance in the north- and south-oriented rooms were compared. Secondly, a characteristic annual profile of the external horizontal illuminance data was determined. Finally, the median external diffuse illuminance data from measurements were compared with values based on the values recommended in the standard. The goal of the research was focused on the evaluation of a regional daylight climate model applicable for daylight evaluations. The results of the daylight illuminance measurements showed the importance of climatic daylight data for indoor daylighting in building design performance.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20103 - Architecture engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1408" target="_blank" >LO1408: AdMaS UP - Pokročilé stavební materiály, konstrukce a technologie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Architectural Engineering
ISSN
1943-5568
e-ISSN
—
Svazek periodika
30
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
14
Strana od-do
1-14
Kód UT WoS článku
001142551000008
EID výsledku v databázi Scopus
2-s2.0-85182599904