Hygrothermal performance of hybrid multi-storey buildings under future climate scenarios
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26110%2F26%3A0200711" target="_blank" >RIV/00216305:26110/26:0200711 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S1359431124025857" target="_blank" >https://www.sciencedirect.com/science/article/pii/S1359431124025857</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.applthermaleng.2024.124917" target="_blank" >10.1016/j.applthermaleng.2024.124917</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Hygrothermal performance of hybrid multi-storey buildings under future climate scenarios
Popis výsledku v původním jazyce
Climate change, energy efficiency, and carbon footprint objectives pose significant challenges to the hygrothermal performance of building structures in climates with extreme temperature variations. To meet long term sustainability targets, buildings designed for a lifespan of up to 100 years must exhibit resilience not only to current climate conditions but also to projected future scenarios. This study evaluated the hygrothermal performance of a hybrid log-concrete multi-storey building, combining the structural strength of concrete with the sustainable, moisture-regulating properties of wood, to address energy efficiency and moisture control challenges in subarctic climates. Onsite measurements were validated using numerical simulations to assess hygrothermal performance of log wall structure under climate change scenarios. Results showed minimal mould growth risk under present conditions, while future climate projections (RCP8.5 for 2080) indicated a maximum mould index of 1.32 near the exterior log surface. These findings highlight the resilience of log-based structures in cold climates and underscore the need for proactive moisture management under warmer, more humid future scenarios. Stable ideal indoor temperatures (averaging 21.56 degrees C to 22.09 degrees C) and effective moisture control (with a maximum average moisture excess of 0.89 g/m3) over the measurement period further demonstrate the suitability of hybrid log-concrete buildings for energy-efficient, moisture-regulating construction in cold climates. The study recommends surface treatments that allow vapour diffusion while preserving wood's hygroscopic qualities to enhance durability in changing climates.
Název v anglickém jazyce
Hygrothermal performance of hybrid multi-storey buildings under future climate scenarios
Popis výsledku anglicky
Climate change, energy efficiency, and carbon footprint objectives pose significant challenges to the hygrothermal performance of building structures in climates with extreme temperature variations. To meet long term sustainability targets, buildings designed for a lifespan of up to 100 years must exhibit resilience not only to current climate conditions but also to projected future scenarios. This study evaluated the hygrothermal performance of a hybrid log-concrete multi-storey building, combining the structural strength of concrete with the sustainable, moisture-regulating properties of wood, to address energy efficiency and moisture control challenges in subarctic climates. Onsite measurements were validated using numerical simulations to assess hygrothermal performance of log wall structure under climate change scenarios. Results showed minimal mould growth risk under present conditions, while future climate projections (RCP8.5 for 2080) indicated a maximum mould index of 1.32 near the exterior log surface. These findings highlight the resilience of log-based structures in cold climates and underscore the need for proactive moisture management under warmer, more humid future scenarios. Stable ideal indoor temperatures (averaging 21.56 degrees C to 22.09 degrees C) and effective moisture control (with a maximum average moisture excess of 0.89 g/m3) over the measurement period further demonstrate the suitability of hybrid log-concrete buildings for energy-efficient, moisture-regulating construction in cold climates. The study recommends surface treatments that allow vapour diffusion while preserving wood's hygroscopic qualities to enhance durability in changing climates.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20301 - Mechanical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
APPLIED THERMAL ENGINEERING
ISSN
1359-4311
e-ISSN
1873-5606
Svazek periodika
259
Číslo periodika v rámci svazku
15.1.2025
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
13
Strana od-do
1-13
Kód UT WoS článku
001360028700001
EID výsledku v databázi Scopus
2-s2.0-85209067017