Stress and reliability analyses of ceramic femoral head of hip joint endoprosthesis, with view to local shape deviations of cone contact areas
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F03%3APU37896" target="_blank" >RIV/00216305:26210/03:PU37896 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Stress and reliability analyses of ceramic femoral head of hip joint endoprosthesis, with view to local shape deviations of cone contact areas
Popis výsledku v původním jazyce
At present, implants are frequently used in clinical practice to return functionality to various parts of the human body. One big group make the implants of joints, one of the most frequently operated joints of the human body being the hip joint. At present, the problems of reliability of ceramic femoral heads for hip joint endoprosthesis are topical, as in a not negligible number of patients their destruction in vivo had taken place. Therefore stress and reliability analyses of the ceramic heads were mmade using computational modelling aimed at finding the causes of the head destruction. In the course of computational modelling it was stated that a pronounced influence on the stress and, hence, the reliability of the ceramic head, had the global and local unevenness of the cone contact areas of the head and the stem. Fig. 1. The stress and reliability studies made up to now have taken into consideration only the influence of model manufacturing inaccuracies, such as deviation from nom
Název v anglickém jazyce
Stress and reliability analyses of ceramic femoral head of hip joint endoprosthesis, with view to local shape deviations of cone contact areas
Popis výsledku anglicky
At present, implants are frequently used in clinical practice to return functionality to various parts of the human body. One big group make the implants of joints, one of the most frequently operated joints of the human body being the hip joint. At present, the problems of reliability of ceramic femoral heads for hip joint endoprosthesis are topical, as in a not negligible number of patients their destruction in vivo had taken place. Therefore stress and reliability analyses of the ceramic heads were mmade using computational modelling aimed at finding the causes of the head destruction. In the course of computational modelling it was stated that a pronounced influence on the stress and, hence, the reliability of the ceramic head, had the global and local unevenness of the cone contact areas of the head and the stem. Fig. 1. The stress and reliability studies made up to now have taken into consideration only the influence of model manufacturing inaccuracies, such as deviation from nom
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Medical Physics and Biomedical Engineering
ISBN
1877040142
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
IFMBE
Místo vydání
Sydney, Australia
Místo konání akce
Sydney
Datum konání akce
24. 8. 2003
Typ akce podle státní příslušnosti
WRD - Celosvětová akce