Stress and Reliability Analyses of Ceramic Femoral Heads with 3D Manufacturing Inaccuracies
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F04%3APU44500" target="_blank" >RIV/00216305:26210/04:PU44500 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388998:_____/04:00103580
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Stress and Reliability Analyses of Ceramic Femoral Heads with 3D Manufacturing Inaccuracies
Popis výsledku v původním jazyce
At present, the problems of reliability of ceramic femoral heads for hip joint endoprosthesis are topical, as in a not negligible number of patients their destruction in vivo had taken place. Therefore stress and reliability analyses of the ceramic headswere made using computational modelling aimed at finding the causes of the head destruction. The deformation and stresses are obtained by computational methods under testing conditions, in accordance with ISO 7206-5. Head reliability is based on the Weiibull weakest link theory. The head's stress and reliability are significantly influenced by manufacturing inaccuracies of the cone contact areas. The considered manufacturing inaccuracies are modelled as axisymmetric or 3D. The effects of manufacturinginaccuracies on the head's hoop stresses along the contact taper are analysed in detail. Finally, the effect of the mentioned manufacturing inaccuracies on the head's failure probability during the loading is shown.
Název v anglickém jazyce
Stress and Reliability Analyses of Ceramic Femoral Heads with 3D Manufacturing Inaccuracies
Popis výsledku anglicky
At present, the problems of reliability of ceramic femoral heads for hip joint endoprosthesis are topical, as in a not negligible number of patients their destruction in vivo had taken place. Therefore stress and reliability analyses of the ceramic headswere made using computational modelling aimed at finding the causes of the head destruction. The deformation and stresses are obtained by computational methods under testing conditions, in accordance with ISO 7206-5. Head reliability is based on the Weiibull weakest link theory. The head's stress and reliability are significantly influenced by manufacturing inaccuracies of the cone contact areas. The considered manufacturing inaccuracies are modelled as axisymmetric or 3D. The effects of manufacturinginaccuracies on the head's hoop stresses along the contact taper are analysed in detail. Finally, the effect of the mentioned manufacturing inaccuracies on the head's failure probability during the loading is shown.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JH - Keramika, žáruvzdorné materiály a skla
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP101%2F01%2FP039" target="_blank" >GP101/01/P039: Stochastický přístup k posouzení spolehlivosti keramických hlavic totální kyčelní endoprotézy</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
The eleventh world congress in mechanism and machine science
ISBN
7-111-14073-7
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
2197-2201
Název nakladatele
IFToMM, China Machine Press
Místo vydání
Tianjin, China
Místo konání akce
Tianjin
Datum konání akce
1. 4. 2004
Typ akce podle státní příslušnosti
WRD - Celosvětová akce