Influence of the Measured Contact Cone Shape Deflections of the Hip Joint Endoprosthesis on the Stress and Reliability Values
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F03%3APU37902" target="_blank" >RIV/00216305:26210/03:PU37902 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388998:_____/03:51030129
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of the Measured Contact Cone Shape Deflections of the Hip Joint Endoprosthesis on the Stress and Reliability Values
Popis výsledku v původním jazyce
The paper presents the results of the computational modelling of the stress states in the ceramic head of the hip joint endoprosthesis. The analysed system is loaded according the ISO 7206-5, the connection between the head and the stem is realised by the self-adhesive cone joint. 3D shape deflections of the mentioned cone areas are considered in the analysed systems. The values of the shape deflections were obtained from the measure device IMS UMPIRE (deflections from the roundness in each measured poiint of the cone areas and the global shape deflection - conicity of the cone). These measured values were implemented to FEM model. The stress and reliability analyses follow. The values of maximum tensile stresses in the head and head's fracture probability curves create dispersion for random head putting on the stem cone.
Název v anglickém jazyce
Influence of the Measured Contact Cone Shape Deflections of the Hip Joint Endoprosthesis on the Stress and Reliability Values
Popis výsledku anglicky
The paper presents the results of the computational modelling of the stress states in the ceramic head of the hip joint endoprosthesis. The analysed system is loaded according the ISO 7206-5, the connection between the head and the stem is realised by the self-adhesive cone joint. 3D shape deflections of the mentioned cone areas are considered in the analysed systems. The values of the shape deflections were obtained from the measure device IMS UMPIRE (deflections from the roundness in each measured poiint of the cone areas and the global shape deflection - conicity of the cone). These measured values were implemented to FEM model. The stress and reliability analyses follow. The values of maximum tensile stresses in the head and head's fracture probability curves create dispersion for random head putting on the stem cone.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
GK - Lesnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP101%2F01%2FP039" target="_blank" >GP101/01/P039: Stochastický přístup k posouzení spolehlivosti keramických hlavic totální kyčelní endoprotézy</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Engineering mechanics 2003
ISBN
80-86246-18-3
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
92-93
Název nakladatele
Institute of Theoretical and Applied Mechanics AS CR Prague
Místo vydání
Svratka
Místo konání akce
Svratka
Datum konání akce
12. 5. 2003
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—